As for aggressive costs, we believe that you will be searching far and wide for anything that can beat us. We can state with absolute certainty that for such high-quality at such rates we have been the lowest around for Uhf Detecting Pd, Tan Delta Test Bridge, Tan Delta Testing Analisys, You may find the lowest price here. Also you will get high quality products and excellent service here! Please do not hesitate to contact us!
China High Quality testing of instrument transformer Manufacturers – GDJF-2006 Partial Discharge Analyzer – HV Hipot Detail:

Features

● With high speed, big capacity data acquisition card. Continuously collect partial discharge data, good repeatability, and high accuracy.
● Functions of testing, analyzing (multi-parameter analysis, two-dimension atlas analysis, three-dimension atlas analysis), data storage, report, and print. Display waveform (ellipse, sine wave, line), discharge value and test voltage.
● Suitable for 50Hz, 150Hz frequency power supply, up to 400Hz. Automatic tracking external power supply frequency.
● Big color LCD screen. Large memory, with USB port.
● With anti-false operation function. Automatic adjusting gain during testing and rectifying.
● Anti-interference design.

Specifications

● Capacitance range: 6pF-250μF
● Sensitivity: <0.02pc (capacitance at 50pF)                  
● Amplifier: 3db low frequency fl 10kHz, 20kHz, 30kHz, 50kHz, 80kHz.   /   3db high frequency fh 100kHz, 200kHz, 300kHz, 400kHz, 500kHz.
● Gain adjustment range>120db, gain difference 20±1db, asymmetry of positive/negative pulse response<1db
● Time window: width 1°-360°, can be rotated at any time.
● Test voltage: 0-200kV, error <3% F.S.
● Acquisition channel: 4 or 6channels/card.
● Input impedance: 1MΩ.
● Max. Sampling rate: 20Mhz.
● AD resolution: 12bit, DC accuracy 0.2%.
● Sampling length of each channel: 8M.
● Triggering mode: Manual, internal triggering, external triggering.
● Bandwidth of acquisition card: 3Mhz(-3db).
● Weight: about 15kg.


Product detail pictures:

China High Quality testing of instrument transformer Manufacturers –  GDJF-2006 Partial Discharge Analyzer – HV Hipot detail pictures

China High Quality testing of instrument transformer Manufacturers –  GDJF-2006 Partial Discharge Analyzer – HV Hipot detail pictures


Related Product Guide:

Well-run devices, expert profits group, and better after-sales companies; We have been also a unified huge family, everybody keep on with the organization worth "unification, determination, tolerance" for China High Quality testing of instrument transformer Manufacturers – GDJF-2006 Partial Discharge Analyzer – HV Hipot , The product will supply to all over the world, such as: Bangladesh, Mecca, Ghana, We hope to have long-term cooperation relationships with our clients. If you are interested in any of our products, make sure you do not hesitate to send enquiry to us/company name. We ensure that you can be totally satisfied with our best solutions!
  • The factory can meet continuously developing economic and market needs, so that their products are widely recognized and trusted, and that's why we chose this company.
    5 Stars By Phyllis from Sheffield - 2017.09.22 11:32
    This company conforms to the market requirement and joins in the market competition by its high quality product, this is an enterprise that have Chinese spirit.
    5 Stars By Andrew Forrest from America - 2018.11.22 12:28

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us