China High Quality testing of transformer Supplier – GDPD-3000C Portable Partial Discharge Detector – HV Hipot
China High Quality testing of transformer Supplier – GDPD-3000C Portable Partial Discharge Detector – HV Hipot Detail:
GDPD-3000C Portable Ultrasonic Partial Discharge Detector uses advanced cloud computing and automatic modeling technology to achieve the partial discharge signal measurement, recording, transmission, storage, analysis and exchange, providing powerful technical support for on-site measurement of partial discharge. The measurement personnel collect the partial discharge information by using GDPD-3000C, and the cloud computing can be used to intelligently diagnose the insulation state of detection equipment in real time.
Specification
Hardware
● Processor: high performance intelligent processor.
● Screen: 4.3inch Touch Screen.
● Operation keys: PVE film keyboard.
● Interface:
● 3.5mm stereo headphone interface
● DC LV current charging interface
● USB 2.0 3G wireless network interface
● TF memory card interface
● External probe sensor interface
● TF memory card: 4G-32G.
● Headphones: Min. 8Ω.
● External probe: Ultrasonic probe extension line 250mm.
● Enclosures material: ABS+PC Plastique.
● Weight: 0.7kg;
● Dimension: 241*126*189mm
Operating Environment
● Operation temperature: 0~55℃.
● Operation humidity: 0~90% RH, non-condensing.
● IP rates: 54.
Ultrasonic Sensor Parameters
● Measuring range: -20dBµV~65dBµV.
● Resolution: 1dB.
● Accuracy: ±1dB.
● Sensitivity: -65dB.
● Frequency: 40kHz.
● Diameter: 16mm.
● Test source: 25dB~35dB.
TEV Parameters
● Sensor: Capacitive.
● Measuring range: 0dBµV~60dBµV.
● Resolution: 1dB.
● Accuracy: ±1dB.
● Max Number of Pulses/Cycle: 655.
● Min number of pulses: 5Hz
Power Supply
● Internal battery: 3.7V, 5.6Ah rechargeable Lithium-ion.
● Typical operating time: approx. 6 hours.
● Battery protection: Auto shutdown time, default 10 mins.
● Rated voltage of charger: 90-264V AC.
● Charging voltage/current: 5V/2.4A.
● Charging Time: approx. 9 hours.
Product detail pictures:



Related Product Guide:
We have been ready to share our knowledge of internet marketing worldwide and recommend you suitable merchandise at most aggressive rates. So Profi Tools present you very best price of money and we are ready to develop alongside one another with China High Quality testing of transformer Supplier – GDPD-3000C Portable Partial Discharge Detector – HV Hipot , The product will supply to all over the world, such as: Cairo, Turkey, Victoria, Today, We are with great passion and sincerity to further fulfill our global customers' needs with good quality and design innovation. We fully welcome customers from all over the world to establish stable and mutually beneficial business relationships, to have a bright future together.

The factory can meet continuously developing economic and market needs, so that their products are widely recognized and trusted, and that's why we chose this company.
