China High Quality Testing Required For Power Circuit Breakers Supplier – GDSL-BX-100 Primary Current Injection Test Set – HV Hipot

China High Quality Testing Required For Power Circuit Breakers Supplier – GDSL-BX-100 Primary Current Injection Test Set – HV Hipot

Brief Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our business puts emphasis on the administration, the introduction of talented personnel, as well as the construction of team building, trying hard to further improve the standard and liability consciousness of staff members customers. Our enterprise successfully attained IS9001 Certification and European CE Certification of Pd Transformer, Capacitor Range, Transformer Winding Resistance Measurement, We believe that our warm and professional service will bring you pleasant surprises as well as fortune.
China High Quality Testing Required For Power Circuit Breakers Supplier – GDSL-BX-100 Primary Current Injection Test Set – HV Hipot Detail:

Features

GDSL-BX-100 Primary Current Injection Test Set application

Specifications

● Power supply: AC 220V 50Hz.
● Output power: 3kVA.
● Output current: 500A in series,1000A in parallel.
● Output voltage: 6V in series, 3V in parallel.
● Current can be adjusted smoothly and continuously. The accuracy is 1.0%.
● Output current is standard sine wave, waveform distortion is less than 5%.
● Output current: RMS continuous adjustable.
● Duty Cycle: 5mins ON, 10mins OFF.

Accessories

Main unit 1 piece
Connection cable 1 piece
2m Output cable 2 pcs 1000A 
Ground cable 1 piece
Power cable 1 piece
User’s guide 1 piece
Factory test report 1 piece

Product detail pictures:

China High Quality Testing Required For Power Circuit Breakers Supplier –  GDSL-BX-100 Primary Current Injection Test Set – HV Hipot detail pictures

China High Quality Testing Required For Power Circuit Breakers Supplier –  GDSL-BX-100 Primary Current Injection Test Set – HV Hipot detail pictures

China High Quality Testing Required For Power Circuit Breakers Supplier –  GDSL-BX-100 Primary Current Injection Test Set – HV Hipot detail pictures

China High Quality Testing Required For Power Circuit Breakers Supplier –  GDSL-BX-100 Primary Current Injection Test Set – HV Hipot detail pictures


Related Product Guide:

In an effort to finest meet up with client's requirements, all of our operations are strictly performed in line with our motto "High High quality, Competitive Rate, Fast Service" for China High Quality Testing Required For Power Circuit Breakers Supplier – GDSL-BX-100 Primary Current Injection Test Set – HV Hipot , The product will supply to all over the world, such as: Turkey, Swansea, Los Angeles, Look forward to the future, we will focus more on the brand building and promotion . And in the process of our brand global strategic layout we welcome more and more partners join us, work together with us based on mutual benefit. Let's develop market by fully utilizing our comprehensive advantages and strive for building.
  • The sales manager is very patient, we communicated about three days before we decided to cooperate, finally, we are very satisfied with this cooperation!
    5 Stars By Lillian from Georgia - 2017.01.28 18:53
    It's really lucky to find such a professional and responsible manufacturer, the product quality is good and delivery is timely, very nice.
    5 Stars By Joanne from South Africa - 2018.03.03 13:09

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us