We always continually provide you with the most conscientious customer service, and the widest variety of designs and styles with finest materials. These efforts include the availability of customized designs with speed and dispatch for Partial Discharge Test Report, Tan Delta Testing Of Transformer, Power Transformer And Instrument Transformer, We warmly welcome clients from all around the world for almost any sort of cooperation with us to build a mutual advantage potential. We've been devoting ourselves wholeheartedly to supply consumers the very best company.
China High Quality transformer oil acidity tester Suppliers – GDND-800 Freezing Point Tester – HV Hipot Detail:

General Information 

1. Transformer oil freezing point tester has the characteristics of exquisite structural design and unique manufacturing process. It conforms to GB/T 3535 and GB/T510 standards and is used to determine the pour point of petroleum products.
2. This instrument adopts compressor refrigeration technology to save energy, simple operation and long service life. Its main technical indicators such as cooling rate and cooling capacity have surpassed similar foreign products.

Working conditions

1. The instrument should be placed on a flat and stable workbench, and air convection should be minimized in the environment.
2. This product may involve flammable materials when used. It is not allowed to have an open flame (or a device that produces spark) close to it during operation.
3. When the instrument is not in use, it should be placed in a dry and ventilated place.
4. The power supply is single-phase three-wire system and must have a good grounding terminal.
5. The environmental conditions for the instrument use are: ambient temperature 5~30℃, humidity ≤85%, working power supply AC220V±10%, 50Hz.

Specification

Refrigerant R13 R502
Cooling time ≤100min (ambient temperature ≤30℃)
Stop interval >30min
Stirring motor power 22W * 2
Stirring motor allows temperature rise 80℃
Power 800W
Voltage 220V±10%, 50Hz±1Hz
Temperature control range room temperature ~ -70℃
Temperature control accuracy ±0.5℃
Temperature display LED
Temperature sensor Pt100
Timer LED

Product detail pictures:

China High Quality transformer oil acidity tester Suppliers –  GDND-800 Freezing Point Tester – HV Hipot detail pictures


Related Product Guide:

As for competitive prices, we believe that you will be searching far and wide for anything that can beat us. We can state with absolute certainty that for such quality at such prices we are the lowest around for China High Quality transformer oil acidity tester Suppliers – GDND-800 Freezing Point Tester – HV Hipot , The product will supply to all over the world, such as: Naples, Slovak Republic, Brasilia, We expect to provide products and services to more users in global aftermarket markets; we launched our global branding strategy by providing our excellent products all over the world by virtue of our well reputed partners letting global users keep pace with technology innovation and achievements with us.
  • This supplier offers high quality but low price products, it is really a nice manufacturer and business partner.
    5 Stars By Nancy from Ottawa - 2018.09.29 17:23
    Factory equipment is advanced in the industry and the product is fine workmanship, moreover the price is very cheap, value for money!
    5 Stars By Claire from Singapore - 2018.12.11 14:13

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us