China High Quality types of earthing test Factory – GD3126A (GD3126B) Insulation Resistance Tester 5kV/10TΩ (10kV/20TΩ) – HV Hipot

China High Quality types of earthing test Factory – GD3126A (GD3126B) Insulation Resistance Tester 5kV/10TΩ (10kV/20TΩ) – HV Hipot

Brief Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our eternal pursuits are the attitude of "regard the market, regard the custom, regard the science" as well as theory of "quality the basic, have faith in the initial and administration the advanced" for Tan Delta Test Equipment Price, Distribution Transformers, Capacitor Discharge Voltage, For anyone who is intrigued in almost any of our solutions or want to talk about a custom made purchase, make sure you sense free of charge to get in touch with us.
China High Quality types of earthing test Factory – GD3126A (GD3126B) Insulation Resistance Tester 5kV/10TΩ (10kV/20TΩ) – HV Hipot Detail:

General Information

GD3126A  (GD3126B) Insulation Resistance Tester is widely used in maintenance of electrical equipment in transformer substation, power plant, etc. It is suitable for carrying out measurement of insulation resistance (IR), absorption ratio (DAR), polarization index (PI), leakage current (Ix) and absorption capacitance (Cx) of all kinds of high voltage equipment, including switchgear, transformers, reactors, capacitors, motors, generators and cables, etc.

Features

● Adopts microcomputer control, menu operation and large LCD screen dot matrix display with stable performance.
● Strong anti-interference ability, suitable for measuring in strong electromagnetic interference environment.
● Large capacity, can meet the requirements of high voltage, high resistance, large capacity load test.
● With shockproof, moisture-proof and dust-proof structure, adapt to the harsh working environment.
● User friendly, display accurate results and data change trends.
● Perfect protection function, able to withstand impact of short circuit and the measured capacitance residual voltage.
● 5 voltage output steps of 250 V, 500V, 1.0kV, 2.5kV, 5.0kV.
● 6 voltage output steps of 250 V, 500V, 1.0kV, 2.5kV, 5.0kV, 10kV. The high voltage of each step is continuously adjustable from zero.
● Output high voltage can also be continuously adjusted.
● Automatic measurement of R15, R60, R600, automatic calculation of absorption ratio, polarization index.
● Maximum resistance measurement range is 0~10TΩ (0~20TΩ), automatic switching range.
● Automatic measurement of ambient temperature, air humidity and test time.
● Displays the test time, buzz tips at every 15 seconds, 5 minutes without operation will prompt shutdown.
● Automatically discharge high voltage after measurement is completed, the discharge time is no more than 30 seconds.
● Storage of 60 groups of measuring results, nonvolatility for 20 years..
● With RS232 serial interface, able to data communicate with computer.
● With external printer, can print measuring results. (optional)
● The voltage of the charged sample is shown before testing and has relevant hints.
● Preset test time, automatically stop measurement;
● Able to detect leakage current Ix and absorption capacitance Cx.

Specifications

Rated test voltage steps

GD3126A (5kV)  GD3126B (10kV)

250V, 500V, 1.0kV, 2.5kV, 5.0kV, 10kV

Output voltage error

±5%

Resistance range

Upper limit

500GΩ~10TΩ

Lower limit

0.1MΩ

Accuracy class

5.0 class

High voltage display error

±( 5%•Ux + 1digital )

Leakage current Ix measuring range & error

0.1nA~9.9mA    5%

Absorption capacitance Cx measuring range & error

0.1pF~99ɥF    5%

Temperature measuring error

±0.5℃

Humidity measuring error

±2%RH

Short circuit current

<6mA

Voltage ripple

<3%

Test time

Up to 99 minues

Insulation resistance

> 500 MΩ (between test wire and case)

Withstand voltage

AC10.0kV 50Hz 1min (between test wire and case)

Power supply

12V lithium battery

Battery service time after one charging

30days 10times DAR & 5times PI test per day

Working temperature and humidity

0℃ ~ + 40℃   < 85%RH

Storage temperature and humidity

- 20℃ ~ + 50℃  < 90%RH

Power Supply

220V AC 50Hz

Dimension (mm)

325 (L)*250(W)*130(H)

Weight

3.7kg

Resistance measuring error

Voltage steps

250 V

500 V

1.0 kV

2.5 kV

5.0 kV

10KV

±( 3%·Rx + 1d )

1GΩ

2GΩ

4GΩ

10GΩ

20GΩ

40GΩ

±( 5%·Rx + 1d )

10GΩ

20GΩ

40GΩ

0.1TΩ

0.2TΩ

0.4TΩ

±( 10%·Rx + 2d )

100GΩ

200GΩ

0.4TΩ

1TΩ

2 TΩ

4TΩ

±( 25%·Rx + 2d )

500GΩ

1TΩ

2TΩ

5TΩ

10TΩ

20TΩ

GD3126A (GD3126B) Packing List

Insulation resistance tester 1 set
Test connecting cable for L terminal (Red) 1 root (1 piece)
Test connecting cable for G terminal (Green) 1 root (1 piece)
Test connecting cable for E terminal (Black) 1 root (1 piece)
3APower adapter (For printer power supply and instrument charging) 1 piece (1 piece)
RS232 Serial communication line 1 root (1 piece)
User’s guide 1 copy (1 piece)
Test Report 1 copy (1 piece)

Packing List

Panel Structure
1. L terminal socket 2. G terminal socket 3. E terminal socket 4. LCD screen
5. Buzzer 6. Temperature & humidity sensor 7. ESC button 8. UP button
9. Contrast knob 10. DOWN button 11. OK button 12. High voltage adjusting knob
13. RS232 interface 14. Power switch 15. Charging socket


Product detail pictures:

China High Quality types of earthing test Factory –  GD3126A (GD3126B) Insulation Resistance Tester 5kV/10TΩ (10kV/20TΩ) – HV Hipot detail pictures

China High Quality types of earthing test Factory –  GD3126A (GD3126B) Insulation Resistance Tester 5kV/10TΩ (10kV/20TΩ) – HV Hipot detail pictures

China High Quality types of earthing test Factory –  GD3126A (GD3126B) Insulation Resistance Tester 5kV/10TΩ (10kV/20TΩ) – HV Hipot detail pictures

China High Quality types of earthing test Factory –  GD3126A (GD3126B) Insulation Resistance Tester 5kV/10TΩ (10kV/20TΩ) – HV Hipot detail pictures

China High Quality types of earthing test Factory –  GD3126A (GD3126B) Insulation Resistance Tester 5kV/10TΩ (10kV/20TΩ) – HV Hipot detail pictures

China High Quality types of earthing test Factory –  GD3126A (GD3126B) Insulation Resistance Tester 5kV/10TΩ (10kV/20TΩ) – HV Hipot detail pictures

China High Quality types of earthing test Factory –  GD3126A (GD3126B) Insulation Resistance Tester 5kV/10TΩ (10kV/20TΩ) – HV Hipot detail pictures

China High Quality types of earthing test Factory –  GD3126A (GD3126B) Insulation Resistance Tester 5kV/10TΩ (10kV/20TΩ) – HV Hipot detail pictures


Related Product Guide:

The corporation upholds the philosophy of "Be No.1 in high quality, be rooted on credit rating and trustworthiness for growth", will continue to serve outdated and new consumers from home and overseas whole-heatedly for China High Quality types of earthing test Factory – GD3126A (GD3126B) Insulation Resistance Tester 5kV/10TΩ (10kV/20TΩ) – HV Hipot , The product will supply to all over the world, such as: Panama, Guinea, Afghanistan, Our company always concentrate on the development of the international market. We have a lot of customers in Russia , European countries, the USA, the Middle East countries and Africa countries. We always follow that quality is foundation while service is guarantee to meet all customers.
  • The company can think what our think, the urgency of urgency to act in the interests of our position, can be said this is a responsible company, we had a happy cooperation!
    5 Stars By Rigoberto Boler from Benin - 2017.12.09 14:01
    Timely delivery, strict implementation of the contract provisions of the goods, encountered special circumstances, but also actively cooperate, a trustworthy company!
    5 Stars By Ryan from Swedish - 2018.06.19 10:42

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us