China High Quality Types Of Primary Current Injection Tests Supplier – GDHL-100B Contact Resistance Tester (Microhm Meter) – HV Hipot
China High Quality Types Of Primary Current Injection Tests Supplier – GDHL-100B Contact Resistance Tester (Microhm Meter) – HV Hipot Detail:
Description
The performance of the conductive circuit of the circuit breaker is important to ensure the safe operation of the switch. The pros and cons of the conductive performance can be reflected by the size of the resistance of the conductive loop. Therefore, the IEC standard and the manufacturer have stipulated that the loop resistance should be measured, and there are clear specifications for the loop resistance of various types of switches. The loop resistance tester is a testing instrument meets the requirements of GB50150-2006 and DL / T 845.4-2004 regulations. It is widely applicable to the measurement of contact resistance, loop resistance, cable, wire, and weld contact resistance of various electrical switches.
Application
● High,middle and low voltage circuit breakers
● High,middle and low voltage disconnecting switches
● High-current bus bar joints
● Cable & Welding joints
It is suitable for high current, micro ohm measuremen
Features
Specifications
Power supply | AC220V±10%, 50Hz |
Power consumption | ≤500W |
Working mode | Output time can be set. |
Test current | 50A, 100A |
Measurement range | 1-1999.9μΩ, resolution 0.01μΩ |
Accuracy | 1%±0.5μΩ |
Constant source output voltage | ≤ 5V |
Working temperature | -20℃~40℃ |
Relative humidity | ≤ 80%RH (no condensate) |
Weight | 5kg |
Accessories
Contact resistance tester | 1 set |
Test lead | 2 pieces |
Power cord | 2 piece |
Fuse | 2 pieces |
Printer paper | 2 rolls |
Standard resistor | 1 piece |
Ground wire | 1 piece |
User’s manual | 1 copy |
Test report | 1 copy |
QC pass | 1 copy |
Packing list | 1 copy |
Product detail pictures:




Related Product Guide:
carry on to further improve, to guarantee merchandise high-quality in line with market and buyer standard necessities. Our organization has a top quality assurance procedure have already been established for China High Quality Types Of Primary Current Injection Tests Supplier – GDHL-100B Contact Resistance Tester (Microhm Meter) – HV Hipot , The product will supply to all over the world, such as: Indonesia, Mumbai, Swaziland, With the technology as the core, develop and produce high-quality merchandise according to the diverse needs of the market. With this concept,the company will continue to develop merchandise with high added values and continuously improve items,and will present many customers with the best goods and services!

This is the first business after our company establish, products and services are very satisfying, we have a good start, we hope to cooperate continuous in the future!
