China High Quality Vlf Test Set Manufacturers – High voltage divider GDFR-D1 – HV Hipot

China High Quality Vlf Test Set Manufacturers – High voltage divider GDFR-D1 – HV Hipot

Brief Description:


Product Detail

Product Tags

Related Video

Feedback (2)

With reliable good quality system, great standing and perfect consumer support, the series of products and solutions produced by our organization are exported to quite a few countries and regions for Transformer Winding Resistance Meter, Uhf Pd Detector, Hv Testing Equipment, We have four leading products. Our products are best sold not only in the Chinese market, but also welcomed in the international market.
China High Quality Vlf Test Set Manufacturers – High voltage divider GDFR-D1 – HV Hipot Detail:

GDFR-D1 series AC/DC Voltage Meter

GDFR-D1 series AC/DC digital meter is on-site instrument, which test both AC and DC voltage. The digital meter and divider are equipped in one unit. 

Features

● Balance type equal potential shield structure.
● Fully-sealed insulation cylinder with internal excellent components.
● High accuracy and linearity, good stability and anti-interference ability.
● With good filling materials, which make the structure smaller and weight lighter, and minimize internal partial discharge.
● Small size, light weight, easy to carry in the field work.
● Inner shield anti-interference system.
● The voltage ratio can be customized, suitable for calibration.
● External voltage meter can be connected.

Technical Specifications

Model No. GDFR-D1-50 GDFR-D1-100 GDFR-D1-150 GDFR-D1-200 GDFR-D1-300 GDFR-D1-400
Voltage(kV) 50 100 150 200 300 400
DC frequency(Hz) <2
AC frequency(Hz) 30-300
Accuracy
(G type)
AC: 1.0%/DC: 0.5%
Accuracy
(H type)
AC: 0.5%/DC: 0.5%
Impedance
(MΩ)
650 1280 2000 2640 4000 5360
Capacitance
(pF)
500 250 400/160 300 200 300
Voltage ratio 1000:1 or 10000:1(or customized)
Height (mm) 500 650 900 1200 1750 2350
Dimension
(mm)
150×150 160×160 200×200 260×260 800×800
Cable impedance(Ω) 50 / 75
Range 1. Low range: 0-20kV
2. High range: 20kV-rated voltage
1. Low range: 0-200kV
2. High range: 200kV-rated voltage
Cable length(m) 3 4 5 6 8 10
Weight(kg) 5.5 6.9 10.6 14.1 23.5 48.2
Packing Medium Imported dry type high polymer materials
Operation temperature 0℃-45℃
Relative humidity <85%RH, no condensation
Altitude <1500m(or customized)
Use condition Indoor use or outdoor use in Sunny day

Product detail pictures:

China High Quality Vlf Test Set Manufacturers –  High voltage divider GDFR-D1 – HV Hipot detail pictures


Related Product Guide:

We are experienced manufacturer. Wining the majority from the crucial certifications of its market for China High Quality Vlf Test Set Manufacturers – High voltage divider GDFR-D1 – HV Hipot , The product will supply to all over the world, such as: Lithuania, Japan, Congo, We've got sufficient experience in producing products according to samples or drawings. We warmly welcome customers from home and abroad to visit our company, and to cooperate with us for a splendid future together.
  • Problems can be quickly and effectively resolved, it is worth to be trust and working together.
    5 Stars By Hilary from Moscow - 2017.04.18 16:45
    This manufacturer can keep improving and perfecting products and service, it is in line with the rules of market competition, a competitive company.
    5 Stars By Eartha from Austria - 2017.02.14 13:19

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us