GDWG-IV SF6 Gas Leak Detector(IR Series)

GDWG-IV SF6 Gas Leak Detector(IR Series)

Brief Description:

GDWG-IV SF6 Gas Leak Detector is infrared red type leak detector(NDIR technology). It is color OLED display and real-time shows SF6 concentration. 


Product Detail

Product Tags

detect SF6 breaker GDWG-IV
infrared leak detector GDWG-IV
Product Description

GDWG-IV SF6 Gas Leak Detector is infrared red type leak detector(NDIR technology). It is color OLED display and real-time shows SF6 concentration. It rapidly detect SF6 breaker, GIS leakage point and yearly leakage rate qualitatively and quantitatively. It’s a good device suitable for power supply department, installation and overhaul unit, power test institute.

Application

High Voltage Switch Equipment
Rotor vane of helicopter
Gas transmission system
To detect fire extinguisher
Ventilation efficiency research of Buildings
To detect danger

Advantages

No radiation.
No need to replace high pressure high pure argon gas regularly.
No need to approach high pressure gas.
No need to replace sensors regularly, cost-effective.
Stable performance, low maintenance cost. No need to make linear calibration every year.
No affect by moisture and environment pollution.
High sensitivity, up to 0.01ppmv.
When serious leakage or the SF6 gas concentration is up to 100%, it will not be polluted or damaged.

Features

OLED display.
Built-in Lithium battery.
User-defined alarm with sound and light.
High sensitivity and good stability.
Fast measurement speed, time is up to 3s.
Temperature and pressure compensation.
Only response for SF6 gas, not for other gas.
Small size, easy to carry, suitable for on-site working.
With gasbag non-slip straps, more comfortable to carry.
Data storage up to 8000groups.
Super-light aluminum with full shielding shell.
External package uses engineering plastic, with water-proof, dust-proof.

Specifications

Measuring principle: Non-dispersive infrared sensor (NDIR)
Measuring range: 0-5000ppm SF6
Accuracy: ±2%FS(0-1000ppm)
Repeatability error: ≤±1%
Sensitivity: 0.01ppmv
Response time: ≤3s
Recovery time: ≤5s
Stability: ≤±20ppm, more than 1000hours
Zero shift: ≤±1%(F.S/year)
Linear error: ≤±1%
Storage temperature: -20~+60℃
Operation temperature: -20~+50℃
Sampling mode: Built-in electromagnetic diaphragm pump, automatic slot-in type, flow up to 1L/min.
Working voltage: 220VAC±10%,50Hz Or Built-in Li-battery.
Dimension: 140×235×83mm
Weight: about 1.5kg

Accessories
CT/PT Tester 1piece
Test Lead 1set
Earth cable 1piece
Power cord 1piece
2A fuse 2pcs
User's guide 1copy
Factory test report 1copy