Insulation & Earth Resistance Tester

  • GDHX-8300F Wireless Phase Detector

    GDHX-8300F Wireless Phase Detector

    GDHX-8300F Wireless Phase Detector is mainly used for phase sequence identification and labeling of power transmission and distribution lines.

    Its working principle is: the phased base station regularly collects the phase signal of a certain area line as a standard signal and uploads it to the main station server. During measurement, the sensor collects the measured line signal and sends it to the handheld device. The handheld device applies to the server for the data of the phasing base station at the same time. By comparing the two phase data, the true phase of the measured line can be calculated.

    The complete set of equipment mainly consists of the main station server, phasing station, handheld machine, sensors and accessories.

  • GDHX-1820 Non-contact High Voltage Detector

    GDHX-1820 Non-contact High Voltage Detector

    GDHX-1820 non-contact high voltage detector is specially designed and manufactured for high-voltage transmission line inspection. The product is used for on-site high-voltage line inspection, identification of high-voltage system voltage level, inspection of high-voltage line faults, repair of neon lights, high-pressure sodium lamps, inspection of induced voltage, and inspection of residual high voltage or induced voltage. 

  • GD2000D Insulation Resistance Tester

    GD2000D Insulation Resistance Tester

    GD2000D digital insulation resistance tester produced by our company uses an embedded industrial single chip real-time operating system. The digital analog pointer and digital field code display are perfectly combined.

     

  • GDF-3000 DC System Earth Fault Detector

    GDF-3000 DC System Earth Fault Detector

    In DC system, there are many earth faults including indirect earth fault, non-metal earth fault, loop earth fault, positive and negative earthing fault, positive and negative balance earth fault, multi-point earth fault.

     

  • GDCR1000C Non-contact Phase Sequence Tester

    GDCR1000C Non-contact Phase Sequence Tester

    GDCR1000C, GDCR1000D non-contact phase tester is a major breakthrough in traditional phase sequence detection method.

  • GDCR-3200C Double Clamp Multifunctional Earth Resistance Tester

    GDCR-3200C Double Clamp Multifunctional Earth Resistance Tester

    GDCR3200C Double Clamp Multifunctional Earth Resistance Tester is specially designed and manufactured for on-site measurement of grounding resistance, soil resistivity, grounding voltage, grounding line leakage current, AC current and DC resistance.

  • GDF-3000A DC System Earth Fault Detector

    GDF-3000A DC System Earth Fault Detector

    DC system insulation faults, DC mutual faults and AC power failures are faults that are prone to occur and are harmful to the power system, and endanger the normal operation of the power system.

  • GDCR3000B Digital Earth Resistance Tester

    GDCR3000B Digital Earth Resistance Tester

    GDCR3000B Earth Resistance/Soil Resistivity Tester is special designed for measuring earth resistance, soil resistivity, earth voltage and AC voltage. The latest digital and micro processing technology is adopted, to measure earth resistance by 4-pole, 3-pole or 2-pole.

     

  • GDDT-10U Digital Grounding Down Lead Earth Continuity Tester

    GDDT-10U Digital Grounding Down Lead Earth Continuity Tester

    GDDT-10U Earth Continuity Resistance Tester is a highly automatic and portable test equipment. It is applied to the measurement of breakover resistance value among earth connecting cables of substation electrical equipment.

  • GDF-5000 Online Insulation Monitoring Device for DC System

    GDF-5000 Online Insulation Monitoring Device for DC System

    GDF-5000/OL Online Insulation Monitoring Device for DC System is used for real-time online monitoring of insulation status of DC bus and branch. This device adopts the detection method of DC balanced resistance.

     

  • GD3128 Series Insulation Resistance Tester

    GD3128 Series Insulation Resistance Tester

    GD3128 series Insulation Resistance Tester has perfect testing function of various insulation resistance parameters and excellent anti-interference ability, which can be used to test the insulation resistance of large capacity high voltage electrical equipment and transmission lines in strong inductive environment such as substation. 

  • GDCO-301 Online Monitoring System of Circulating Current on Cable Sheath

    GDCO-301 Online Monitoring System of Circulating Current on Cable Sheath

    Cables above 35kV are mainly single-core cables with metal sheath. Since the metal sheath of the single-core cable is hinged with the magnetic field line generated by the AC current in the core wire, the two ends of the single-core cable have a high induced voltage.

12 Next > >> Page 1 / 2

Send your message to us:

Write your message here and send it to us