OEM Best Automatic dew point meter Exporters – GDBS-305 Automatic Flash Point Closed Cup Tester – HV Hipot
OEM Best Automatic dew point meter Exporters – GDBS-305 Automatic Flash Point Closed Cup Tester – HV Hipot Detail:
General Information
GDBS-305 automatic closed cup flash point tester is the device testing closed cup flash point for petroleum products. It use module design which one host can control several testing furnace, to test different samples at the same time or separately. The testing furnace port can be connected to the host disorderly. It widely used in the field of railway, air company, power, petroleum and research department.
Features
● 320*240 TFT LCD screen.
● With high speed signal processor control, reliable and high accuracy.
● One host can control several test furnace to test several samples at one time, which will save testing time.
● Automatic ignition with no gas source ignition mode.
● Built-in atmosphere pressure sensor, auto-measure and calibrate result.
● Self-adaptive PID control calculation, automatic adjusting temperature rise curve according to standard requirements.
● Procedures including temperature rise,uncap,ignition,alarm,cooling,print are realized automatically.
● With fault auto-detection alarm function.When sensor fault,sample mistake,temperature over value,the instrument will stop automatically and alarm.
● Built-in high speed thermal printer.
● Store up to 255pcs history records.
Specifications and Attentions
● Temperature measure range: -59.9℃–299.9℃
● Temperature control range: room temperature–299.9℃
● Repeatability: 0.025X(X is average value of test result for continuous twice test)
● Resolution: 0.1℃
● Thermometric sensor: Pt resistance(A grade PT100)
● Flash fire sensor: Thermocouple
● Power voltage: AC220V±20% 50HZ±10%
● Max.Power: 400W
● Environmental temperature: 0℃-40℃
● Relative humidity: ≤85% RH
● Weight: 18kg
● Dimension: 480*260*300mm
Product detail pictures:




Related Product Guide:
Every single member from our higher effectiveness product sales staff values customers' requires and organization communication for OEM Best Automatic dew point meter Exporters – GDBS-305 Automatic Flash Point Closed Cup Tester – HV Hipot , The product will supply to all over the world, such as: Swedish, Algeria, Germany, To get more information about us as well as see all our products, please visit our website. To get more information please feel free to let us know. Thank you very much and wish your business always be great!

The company can think what our think, the urgency of urgency to act in the interests of our position, can be said this is a responsible company, we had a happy cooperation!
