OEM Best Capacitance Setting Multimeter Factory – AC DC High Voltage Divider – HV Hipot
OEM Best Capacitance Setting Multimeter Factory – AC DC High Voltage Divider – HV Hipot Detail:
GDFR-C1 series AC/DC Voltage Meter
GDFR-C1 series AC/DC digital meter is on-site instrument, which test both AC and DC voltage. It consists of voltage divider and measurement instrument.
Features
● Balance type equal potential shield structure.
● Fully-sealed insulation cylinder with internal excellent components.
● High accuracy and linearity, good stability and anti-interference ability.
● The voltage ratio can be customized, suitable for calibration.
● Upside down is forbidden when installation.
Technical Specifications
Model No. | GDFR-C1-50 | GDFR-C1-100 | GDFR-C1-150 | GDFR-C1-200 | GDFR-C1-300 | GDFR-C1-400 |
Voltage(kV) | 50 | 100 | 150 | 200 | 300 | 400 |
DC frequency (Hz) | <2 | |||||
AC frequency (Hz) | 30-300 | |||||
Accuracy | AC: 1.5%/DC: 1.0% | |||||
Accuracy for option (G type) | AC: 1.0%/DC: 0.5% | – | ||||
Accuracy for option (H type) | AC: 0.5%/DC: 0.5% | – | – | |||
Impedance (MΩ) |
650 | 1280 | 2000 | 2640 | 4000 | 5360 |
Capacitance (pF) |
320 | 250 | 400 / 160 | 300 | 200 | 300 |
Voltage ratio | 1000:1 or 10000:1(or customized) | |||||
Dimension (mm) |
150×150 | 160×160 | 350×350 | 800×800 | 1000×1000 | |
Cable impedance(Ω) | 50 / 75 | |||||
Range | 1. Low range: 0-20kV 2. High range: 20kV-rated voltage 3. Low range: 0-200kV 4. High range:200kV-rated voltage |
|||||
Cable length(m) | 3 | 4 | 6 | 6 | 10 | 10 |
Weight(kg) | 5.5 | 9.5 | 12.5 | 14.5 | 27 | 40 |
Packing Medium | Polyurethane foaming agent | |||||
Operation temperature | 0℃-45℃ | |||||
Relative humidity | <85%RH, no condensation | |||||
Altitude | <1500m (or customized) | |||||
Use condition | Indoor use or outdoor use in Sunny day |
Product detail pictures:



Related Product Guide:
We retain bettering and perfecting our merchandise and service. At the same time, we do the job actively to do research and improvement for OEM Best Capacitance Setting Multimeter Factory – AC DC High Voltage Divider – HV Hipot , The product will supply to all over the world, such as: Germany, Indonesia, Toronto, Our products have won an excellent reputation at each of the related nations. Because the establishment of our firm. we have insisted on our production procedure innovation together with the most recent modern day managing method, attracting a sizable quantity of talents within this industry. We regard the solution good quality as our most vital essence character.

The sales person is professional and responsible, warm and polite, we had a pleasant conversation and no language barriers on communication.

Send your message to us:
Write your message here and send it to us