OEM Best Capacitor Discharge Voltage Supplier – Insulation Materials Hipot Test Set GDJS-65 – HV Hipot

OEM Best Capacitor Discharge Voltage Supplier – Insulation Materials Hipot Test Set GDJS-65 – HV Hipot

Brief Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We're proud from the higher client fulfillment and wide acceptance due to our persistent pursuit of high quality both on product and service for Capacitor Features, Testing A Capacitor With A Voltmeter, Capacitor For Transformer, Your inquiry might be extremely welcomed plus a win-win prosperous development are what we've been expecting.
OEM Best Capacitor Discharge Voltage Supplier – Insulation Materials Hipot Test Set GDJS-65 – HV Hipot Detail:

GDJS-65 Insulation Gloves Test Set

It is used to test insulation performance for insulation gloves, boots, mats, hats, rod, Electroscope etc. It can test 6pcs insulation gloves/boots at the same time, also 5pcs insulation rods.

Features

Manual control unit
● Digital and real time display HV voltage, LV current, 6-way leak current and time.
● With leak current meter and over-current protection meter.
● With movable control unit, easy wiring and testing.
● Manual control, safety and reliability.
● With zero, power, operation, timing indicators.
● With over-current protection, zero-start protection, sound and light alarm, power protected switch.
● New type timer, broader timing range.(1s-99h).

Other features
● HV source is oil immersed type testing transformer.(dry type and SF6 gas type for option.)
● It is suitable for testing insulation gloves(boots), 6-110kV insulation rod and 6-110kV electroscope.
● To make test for insulation gloves and boots, the HV electrode is chain type, which the height can be adjusted. The material is stainless steel with CU/EpNi5bc painted, which make surface discharge<10pc. 6pcs insulation barrels are also supplied.
● The electrode of insulation boots is red cooper voltage-sharing type, the HV inside the bottom of boots are equal distribution. 4mm steel balls supplied, not using traditional way that injecting water.
● With insulation rod stand to make withstand voltage and leak test for insulation rod.(Optional)
● With electroscope testing device to make start voltage, in-phase, out-phase interference test for electroscope. (Optional)
● With electrode for withstand voltage and leak test of insulation mat and blanket. (Optional)
● Control unit and HV unit are separate, to ensure safety.
● If there is breakdown or over limits, the HV output will be cut off automatically and alarm.

Specifications

● Rated capacity: 5kVA
● Input voltage: AC220V±10%, 50Hz±1
● Output voltage: 0-50kV
● Voltage accuracy: ≤ 2.0%(F.S)
● LV current: 0-25A
● Leak current: 0-20.0mA
● Resolution of leak current: 0.1mA
● Current accuracy: ≤1.5%
● Timing range: 0-99h
● Environmental temperature: -20℃-50℃


Product detail pictures:

OEM Best Capacitor Discharge Voltage Supplier –  Insulation Materials Hipot Test Set GDJS-65 – HV Hipot detail pictures

OEM Best Capacitor Discharge Voltage Supplier –  Insulation Materials Hipot Test Set GDJS-65 – HV Hipot detail pictures

OEM Best Capacitor Discharge Voltage Supplier –  Insulation Materials Hipot Test Set GDJS-65 – HV Hipot detail pictures


Related Product Guide:

We know that we only thrive if we can guarantee our combined price tag competiveness and top quality advantageous at the same time for OEM Best Capacitor Discharge Voltage Supplier – Insulation Materials Hipot Test Set GDJS-65 – HV Hipot , The product will supply to all over the world, such as: Latvia, Melbourne, Porto, Furthermore, all of our items are manufactured with advanced equipment and strict QC procedures in order to ensure high quality. If you are interested in any of our goods, please don't hesitate to contact us. We will do our best to meet your needs.
  • Staff is skilled, well-equipped, process is specification, products meet the requirements and delivery is guaranteed, a best partner!
    5 Stars By Josephine from Iran - 2018.06.21 17:11
    Perfect services, quality products and competitive prices, we have work many times, every time is delighted, wish continue to maintain!
    5 Stars By Hannah from Iran - 2017.11.20 15:58

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us