OEM Best Capacitor Tan Delta Factories – AC DC High Voltage Divider – HV Hipot
OEM Best Capacitor Tan Delta Factories – AC DC High Voltage Divider – HV Hipot Detail:
GDFR-C1 series AC/DC Voltage Meter
GDFR-C1 series AC/DC digital meter is on-site instrument, which test both AC and DC voltage. It consists of voltage divider and measurement instrument.
Features
● Balance type equal potential shield structure.
● Fully-sealed insulation cylinder with internal excellent components.
● High accuracy and linearity, good stability and anti-interference ability.
● The voltage ratio can be customized, suitable for calibration.
● Upside down is forbidden when installation.
Technical Specifications
Model No. | GDFR-C1-50 | GDFR-C1-100 | GDFR-C1-150 | GDFR-C1-200 | GDFR-C1-300 | GDFR-C1-400 |
Voltage(kV) | 50 | 100 | 150 | 200 | 300 | 400 |
DC frequency (Hz) | <2 | |||||
AC frequency (Hz) | 30-300 | |||||
Accuracy | AC: 1.5%/DC: 1.0% | |||||
Accuracy for option (G type) | AC: 1.0%/DC: 0.5% | – | ||||
Accuracy for option (H type) | AC: 0.5%/DC: 0.5% | – | – | |||
Impedance (MΩ) |
650 | 1280 | 2000 | 2640 | 4000 | 5360 |
Capacitance (pF) |
320 | 250 | 400 / 160 | 300 | 200 | 300 |
Voltage ratio | 1000:1 or 10000:1(or customized) | |||||
Dimension (mm) |
150×150 | 160×160 | 350×350 | 800×800 | 1000×1000 | |
Cable impedance(Ω) | 50 / 75 | |||||
Range | 1. Low range: 0-20kV 2. High range: 20kV-rated voltage 3. Low range: 0-200kV 4. High range:200kV-rated voltage |
|||||
Cable length(m) | 3 | 4 | 6 | 6 | 10 | 10 |
Weight(kg) | 5.5 | 9.5 | 12.5 | 14.5 | 27 | 40 |
Packing Medium | Polyurethane foaming agent | |||||
Operation temperature | 0℃-45℃ | |||||
Relative humidity | <85%RH, no condensation | |||||
Altitude | <1500m (or customized) | |||||
Use condition | Indoor use or outdoor use in Sunny day |
Product detail pictures:



Related Product Guide:
In an effort to provide you advantage and enlarge our business enterprise, we even have inspectors in QC Staff and assure you our greatest provider and item for OEM Best Capacitor Tan Delta Factories – AC DC High Voltage Divider – HV Hipot , The product will supply to all over the world, such as: Ireland, Sevilla, Singapore, Our company is working by the operation principle of "integrity-based, cooperation created, people oriented, win-win cooperation". We hope we can have a friendly relationship with businessman from all over the world

The accounts manager made a detailed introduction about the product, so that we have a comprehensive understanding of the product, and ultimately we decided to cooperate.

Send your message to us:
Write your message here and send it to us