Well-run products, skilled income group, and better after-sales products and services; We have been also a unified massive family, all people stick with the business price "unification, dedication, tolerance" for Insulation Transformer, After A Capacitor Is Discharged, Dc Voltage Tester, You would not have any communication problem with us. We sincerely welcome customers all over the world to contact us for business cooperation.
OEM Best Coupling Capacitor Use Exporters – AC Resonant Test System for Generators GDTL – HV Hipot Detail:

GDTL series AC Resonant Test System for Generators can be used by adjusting inductance of the reactor, or adjusting the work way of resonant frequency of the system to achieve resonance. Both two methods can be used to achieve resonance. In the voltage boosting process, if the resonant point deviate, it can be found exactly by the way of fine tuning frequency, which ensure a high Q value and reduce power capacity and volume weight of test equipment.

Features

● Smaller size,lighter weight compared with same voltage level,same capacity generator AC withstand voltage test equipment.Single equipment is no more than 60kg, easy to move.
● Advanced principle of whole set device and new frequency & inductance modulation technology, strictly ensure generator power frequency withstand voltage test requirements. Wide application scope.
● Equipped with 20Hz-300Hz variable control source. Good protection and output waveform, high stability. With multiple working mode,easy to operate.
● Power supply of 220V or 380V, convenient for on-site power sourcing。
● Max.Q point can be found exactly by the mode of first inductance modulation and later frequency modulation, to avoid resonance deviation because of voltage boosting;
● Flexible configuration and strong extension. Meet all capacitive test object testing requirements in power system.
● Power frequency test mode or Variable frequency test mode.
● Multi-use, cost-effective.

Specifications

● Rated output voltage: 0 ~ 50kV (RMS) or below.
● Output frequency: 45 – 300Hz.
● Waveform: pure sine wave, THD ≤ 1%.
● Max. capacity: 2000kVA or below.
● Duty cycle: continuous working 15mins one time at full power output.
● Quality factor: 10 – 40.
● Frequency adjustment sensitivity: 0.1HZ, instability of <0.05%.
● Power supply: 220V or 380V ± 15%, 50HZ ± 5%.

GDTF- 100/50

Input voltage (V)

380

Output voltage (kV)

0- 50

Capacity (kVA)

100

Application scope

Generator–capacitance to the ground 0.07-0.13 μF

10 kV (300 mm² ) cable ≤ 1 km

Main configurations

50kV/1A Fixed reactor 1 set

50kV/1A Adjustable reactor 1 set

Capacitive divider 50kV

GDTF-150/50

Input voltage (V)

380

Output voltage (kV)

0- 50

Capacity (kVA)

150

Application scope

Generator–capacitance to the ground 0.13-0.2 μF

10 kV (300 mm² ) cable ≤ 1.5 km

Main configurations

50kV/1.5A Fixed reactor 1 set

50kV/1.5A Adjustable reactor 1 set

Capacitive divider 50 kV

GDTF- 225/50

Input voltage (V)

380

Output voltage (kV)

0- 50

Capacity (kVA)

225

Application scope

Generator–capacitance to the ground 0.2-0.27 μF

10 kV (300 mm ² ) cable ≤ 2.5 km

Main configurations

50kV/1.5A Fixed reactor 2 sets

50kV/1.5A Adjustable reactor 1 set

Capacitive divider 50 kV

GDTF- 360/60

Input voltage (V)

380

Output voltage (kV)

0- 60

Capacity (kVA)

360

Application scope

Generator–capacitance to the ground 0.27-0.33 μF

Main configurations

60kV/2A Fixed reactor 1 set

60kV/2A Adjustable reactor 1 set

Capacitive divider 60kV


Product detail pictures:

OEM Best Coupling Capacitor Use Exporters –  AC Resonant Test System for Generators GDTL – HV Hipot detail pictures

OEM Best Coupling Capacitor Use Exporters –  AC Resonant Test System for Generators GDTL – HV Hipot detail pictures


Related Product Guide:

We are going to make every single effort for being excellent and excellent, and accelerate our ways for standing while in the rank of international top-grade and high-tech enterprises for OEM Best Coupling Capacitor Use Exporters – AC Resonant Test System for Generators GDTL – HV Hipot , The product will supply to all over the world, such as: Sheffield, Irish, Ghana, Our company offers the full range from pre-sales to after-sales service, from product development to audit the use of maintenance, based on strong technical strength, superior product performance, reasonable prices and perfect service, we will continue to develop, to provide the high-quality products and services, and promote lasting cooperation with our customers, common development and create a better future.
  • This manufacturer can keep improving and perfecting products and service, it is in line with the rules of market competition, a competitive company.
    5 Stars By Mag from United States - 2018.06.03 10:17
    The quality of the products is very good, especially in the details, can be seen that the company work actively to satisfy customer's interest, a nice supplier.
    5 Stars By Grace from Philadelphia - 2017.09.28 18:29

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us