OEM Best dew point measuring instrument for transformer oil Manufacturer – GDZL-503 Automatic Interfacial Tension tester – HV Hipot
OEM Best dew point measuring instrument for transformer oil Manufacturer – GDZL-503 Automatic Interfacial Tension tester – HV Hipot Detail:
Intermolecular forces will generate interface tension and surface tension of liquids. The value of tension reflects liquid sample’s physics and chemical properties, which is one of the most important index for product quality.
GDZL-503 automatic interfacial tension tester tests kinds of liquid surface tension and interface tension according to ring method which is simple and accurate. It is widely used in electric, petroleum, chemical,medicine, food and teaching filed.
Features
● Exclusive and quick response electromagnetic balance sensor is adopted, to improve the accuracy of the measurement and degree of linearity.
● Only using one point calibration, to solve the problem of previous sensor which needs multi-point calibration. It is no need to use zero potentiometer and full scale potentiometer.
● Real-time show equivalent tension value and current weight.
● Integrated with temperature detection circuit, to compensate temperature automatically for test result.
● 240*128 dot matrix LCD screen.No logo button has function of screen protection.
● Save up to 255 history records with time indicated.
● Built in high speed thermal mini printer to print out quickly. It also has function of offline print.
● With RS232 port, to connect with PC directly.
Specification
Measuring range | 0-200mN/m |
Accuracy | 0.1% of the reading±0.1 mN/m |
Resolution | 0.1mN/m |
Sensitivity | 0.1mN/m |
Power supply | AC220V±20%,50Hz±10% |
Maximum power consumption | 20W |
Environmental temperature | 10~30℃(25℃ is the best) |
Environmental humidity | ≤85% RH |
Dimension | 200×300×330(mm) |
Weight | 6kg |
Product detail pictures:


Related Product Guide:
We often stay with the principle "Quality Very first, Prestige Supreme". We have been fully committed to supplying our consumers with competitively priced high-quality goods, prompt delivery and skilled provider for OEM Best dew point measuring instrument for transformer oil Manufacturer – GDZL-503 Automatic Interfacial Tension tester – HV Hipot , The product will supply to all over the world, such as: Angola, Indonesia, Guatemala, We adopted technique and quality system management, based on "customer orientated, reputation first, mutual benefit, develop with joint efforts", welcome friends to communicate and cooperate from all over the world.

Managers are visionary, they have the idea of "mutual benefits, continuous improvement and innovation", we have a pleasant conversation and Cooperation.
