We depend on sturdy technical force and continually create sophisticated technologies to meet the demand of Testing A Capacitor With A Voltmeter, Capacitance Bridge, Capacitance Standard, If possible, be sure to send your needs with a detailed list including the style/item and quantity you require. We will then deliver our greatest price ranges to you.
OEM Best Discharge Ac Capacitor With Multimeter Manufacturers – Partial Discharge Test System GDYT series – HV Hipot Detail:

GIT Series GIS High Voltage Test Sets integrate the high voltage boosting, high voltage measurement, high voltage transformer, high voltage coupling capacitors and all components in a sealed space.
There are two modes to generate high voltage
1) Using reactor inductance and test object capacitance to realize voltage resonance test, to obtain a high voltage, high current from test object.
2) The other one is to obtain required high voltage directly from high voltage transformer.

It is widely used for high voltage, big capacity GIS power equipment insulated withstand voltage test, partial discharge test and GIS transformer accuracy test, suitable for GIS substation, GIS power equipment manufacturer, basin type electrical insulator manufacturer.

Electrical testing equipment
High voltage measurement
Features

● The High voltage obtained are well sealed and shielded in containers, protect the safety of person, no outside interference.
● Accurate test measurement.
● If adding a high voltage sleeve interface, it can lead to high voltage, that can do various high voltage test to traditional high voltage equipment.
● The safest type of high voltage test.

Partial discharge test
pd test of transformer
Specifications

● Output voltage: 100kV, 200kV, 250kV, 300kV, 500kV, 750kV, 1000kV, based on different test objects.
● Capacity: 50-2000kVA, based on different test objects.
● High voltage generated mode: high voltage transformer voltage boost and series resonance (power frequency, frequency conversion).
● All methods of boost voltage are one level voltage boost, no need to cascade boost voltage.
● Input voltage: 0.35-10kV.
● Partial discharge: Rated voltage 3pc (normal environment).
● Impedance voltage: 5%.
● Temperature rise: no more than 65k (50Hz) when rated current operates 60mins.

Power test equipment
PD transformer


Product detail pictures:

OEM Best Discharge Ac Capacitor With Multimeter Manufacturers –  Partial Discharge Test System GDYT series – HV Hipot detail pictures

OEM Best Discharge Ac Capacitor With Multimeter Manufacturers –  Partial Discharge Test System GDYT series – HV Hipot detail pictures


Related Product Guide:

abide by the contract", conforms to the market requirement, joins during the market competition by its superior quality also as provides extra comprehensive and exceptional service for consumers to let them turn into significant winner. The pursue of the business, is definitely the clients' gratification for OEM Best Discharge Ac Capacitor With Multimeter Manufacturers – Partial Discharge Test System GDYT series – HV Hipot , The product will supply to all over the world, such as: Cancun, Albania, French, We have established long-term, stable and good business relationships with many manufacturers and wholesalers around the world. Currently, we are looking forward to even greater cooperation with overseas customers based on mutual benefits. Please feel free to contact us for more details.
  • This enterprise in the industry is strong and competitive, advancing with the times and develop sustainable, we are very pleased to have a opportunity to cooperate!
    5 Stars By Doris from Turkey - 2018.09.19 18:37
    A good manufacturers, we have cooperated twice, good quality and good service attitude.
    5 Stars By Eileen from San Francisco - 2017.02.28 14:19

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us