OEM Best electric tester meter Suppliers – GDDO-20C AC/DC Electric Meter Calibration Device – HV Hipot
OEM Best electric tester meter Suppliers – GDDO-20C AC/DC Electric Meter Calibration Device – HV Hipot Detail:
General Information
GDDO-20C AC/DC Electric Meter Calibration Device is used to detect basic error of various power frequency electric instruments in power systems, including voltmeter, ammeter, wattmeter, ohmmeter, single phase & three phase AC energy meters (optional) and basic error of DC volt-meter and ammeter.
For meter’s part, it takes high precision power frequency AC collector as core technology, which consists of digital signal processor (DSP) and 16-digit high speed analog-digital converter; For signal source, it uses DSP and 16-digit high speed analog-digital converter to form signal source that produces sine wave signal and distortion wave signal.
Features
● Accuracy class of 0.05. When AC voltage, AC current and active power are measured, the device is equipped with a digital/frequency converter (DFC) with a working frequency higher than 60kHz and multiple current ranges, so high accuracy is guaranteed.
● The distortion wave of 2~31 times, number, times and amplitude of harmonics, and phase of harmonic to fundamental wave can be all programmed.
● 6.5-inch color TFT LCD screen, clear and bright display.
● With RS232 communication port.
● With a large capacity non-volatile memory, can store test results of 300 meters under test, support data view and data upload function.
● With good reliability, easy to operate.
Specification
Power frequency AC output |
|
Voltage range (V) |
50, 100, 200, 400, 600 (800V is optional), Max. output capacity 20VA |
Current range (A) |
0.5, 1, 2.5, 5, 10, 20, Max. output capacity 20VA |
Voltage adjustment range |
0~130%, fineness adjustment 5*10 |
Current adjustment range |
0~130%, fineness adjustment 5*10 |
Accuracy of voltage, current, active power and energy |
0.05% |
Accuracy of reactive power and energy |
0.1% |
Phase accuracy of current to phase voltage |
0.05° |
Frequency |
Adjustment range: 45~65Hz, Fineness adjustment: 0.001Hz Setting value accuracy: 0.01Hz |
Phase |
Adjustment range: 0~359.99° Fineness adjustment: 0.01° Setting value accuracy: 0.05° |
Distortion degree of voltage and current output waveform |
≤0.3% |
Stability of voltage, current and power output |
≤0.01%/60s (peak-to-peak value) |
Harmonics |
2~31 times Amplitude: 0~20% Phase fineness: 0.01°*N (“N” refers to harmonic order) |
DC output |
|
Voltage range (V) |
0.075, 75, 150, 300, 500, 1000, Max. output capacity 20W |
Current range (A) |
0.5, 1, 2.5, 5, 10, 20, Max. output capacity 20W |
Adjustment range of voltage and current |
0~120% (not including 1000V), fineness adjustment 5*10 |
Stability of voltage and current output |
≤0.01%/60s (peak-to-peak value) |
Accuracy of voltage setting value |
0.05% |
Accuracy of current setting value |
0.1% |
Accuracy at 75mV output (Load ≥5Ω) |
0.1% |
General parameters |
|
Power supply |
Single phase 220V±10%, 50Hz±5% |
Use conditions |
20℃±10℃, ≤85%RH |
Dimension |
460*460*175mm |
Weight |
About 20kg |
Packing List
Main unit | 1 set |
Aluminum alloy box | 1 set |
Power cord | 1 pc |
Test line with connector | 1 pc |
Test line (DC 75mV) | 1 pc |
Test line for electric energy pulse | 1 pc |
Communication cable | 1 pc |
Photoelectric collector | 1 pc |
User’s guide | 1 copy |
Factory test report | 1 copy |
Product detail pictures:

Related Product Guide:
Our firm has been concentrating on brand strategy. Customers' satisfaction is our best advertising. We also offer OEM provider for OEM Best electric tester meter Suppliers – GDDO-20C AC/DC Electric Meter Calibration Device – HV Hipot , The product will supply to all over the world, such as: Mongolia, Belgium, Cape Town, Our company insists on the purpose of "takes service priority for standard, quality guarantee for the brand, do business in good faith, to offer skilled, rapid, accurate and timely service for you". We welcome old and new customers to negotiate with us. We are going to serve you with all sincerity!

The accounts manager made a detailed introduction about the product, so that we have a comprehensive understanding of the product, and ultimately we decided to cooperate.
