OEM Best energy meter calibration Suppliers – GDYB-S6 Three Phase Energy Meter Test Bench – HV Hipot
OEM Best energy meter calibration Suppliers – GDYB-S6 Three Phase Energy Meter Test Bench – HV Hipot Detail:
6-position Meter Test Bench (Three Phase)
Main Features&Functions
● Compact design, the meter rack of the testing equipment and the desk frame are all made of special aluminum alloy and the desk face-plate is made of fireproof and heatproof fiber material.
● Easy to use, both keyboard and PC operation are available.
● Advanced automation. User only needs to put on meters, adjust the photoelectric sampler and set the parameters in good condition, then all the test items, including pre-heating, actuation and false actuation tests, standard deviation test, basic error test are controlled by PC by one test. The procedure of meter calibration can be user-defined.
● Photoelectric sampler can realize three-dimensional adjustment. It can not only sample the turn-plate signal of the rotary meter but also receive the strobe signal of the electronic meter.
● The error processing system can receive signal from the photoelectric sampler and output pulse of the insert type electronic meter, and high frequency pulse signal of standard meter.
● Meters in same type(same phase line, rated voltage, calibrated current) but different constant (at most 3 kinds) can be test at same time.
● Test RS485 communication function of multi-functional meter, required error and clocking error is optional(Time signal output is necessary).
● Locate the mark area of rotary meter automatically, which enables easier false actuation tests.
● Superimposing 2 to 21 harmonics in fundamental wave of power frequency, harmonic amplitude and phase can be set according the requirements. Also harmonic analysis and draw waveform can be performed for output components.
● Auto testing on every unit voltage, current, power stability and three phase total power stability.
● High stability and reliability, which can provide strong output power. Voltage (current) loop can take load of any type.
● The testing equipment is provided with complete malfunction checking, locating, protecting and alarming functions to avoid damaging of the bench resulted from wrong manual wiring or operating.
● PC software provides complete functions, such as report printing, quantity counting and assets maintaining
Specification
● Accuracy level: 0.05%
● Output voltage: 3*100V/57.7V Y 3*100V ∆
3*380V/220V Y 3*380V ∆
Regulating range: 0-120% consecutively adjustable
Regulating accuracy: better than 0.01%
* Special voltage range can be setup according to actual order.
● Current range: 0.1A, 0.25A, 0.5A, 1A, 2.5A, 5A, 10A, 20A, 50A, 100A
Regulating range: 0-120% consecutively adjustable
Regulating accuracy: better than 0.01%
● Output power: (voltage loop) GDYB-S6 100VA
(current loop) GDYB-S6 150VA
● Stability of output voltage, current and power:
≤0.02%/120S PF=1 (Class 0.05)
≤0.05%/120S PF=1 (Class 0.1)
● Wave distortion of output voltage and current: ≤0.5%
● Symmetry of three phase: better than 120°+0.3°
● Frequency range: 45Hz-65Hz regulating accuracy: 0.01 Hz
● Phase shifting range: -180.0°-180.0° regulating accuracy: 0.1°
● Standard crystal oscillator stability: ≤10-7/s
● Indicating instruments class
Voltmeter and ammeter accuracy: level ±0.2%
Phase meter accuracy: ±0.5°
Frequency meter accuracy: ±0.01Hz
● Maximum meters for test: 6
● Power supply: 3*220V±10%, 50Hz (or 120V±10%, 60Hz)
● Maximum power consumption: 1500VA
● Working temperature: 20±5℃ relative humidity: ≤85%
● Dimensions and weight:
2000mm*720 mm*1550mm 280Kg
Product detail pictures:




Related Product Guide:
We'll make each hard work to become excellent and excellent, and speed up our measures for standing from the rank of intercontinental top-grade and high-tech enterprises for OEM Best energy meter calibration Suppliers – GDYB-S6 Three Phase Energy Meter Test Bench – HV Hipot , The product will supply to all over the world, such as: Nigeria, panama, Durban, We have now a large share in global market. Our company has strong economic strength and offers excellent sale service. Now we have established faith, friendly, harmonious business relationship with customers in different countries. , such as Indonesia, Myanmar, Indi and other Southeast Asian countries and European, African and Latin American countries.

This enterprise in the industry is strong and competitive, advancing with the times and develop sustainable, we are very pleased to have a opportunity to cooperate!
