With a positive and progressive attitude to customer's interest, our enterprise continually improves our products excellent to meet the wants of customers and further focuses on safety, reliability, environmental requirements, and innovation of Pd Monitoring System, Capacitor Capacitance, Dissipation Factor Tan Delta, At our firm with quality first as our motto, we manufacture products that are entirely made in Japan, from materials procurement to processing. This enables them to be used with confident peace of mind.
OEM Best High Voltage Pulse Generator Factory – GD6100C Transformer Insulation Oil Tan Delta Tester/Oil Dielectric Tester – HV Hipot Detail:

General Information

GD6100C Automatic Precision Oil Dielectric Loss Tester, is used for measuring dielectric dissipation factor and DC resistivity of insulating oil and other insulating liquids. The instrument intergrates with test oil cell, temperature controller, temperature sensor, dielectric loss test bridge, AC test power, standard capacitor, high resistance meter, DC high voltage source and other major components. 

Features

● The test cell adopts the three-electrode structure according to national standard GB/T5654-2007, with electrode spacing 2mm, which can eliminate the effects of the stray capacitance and leakage on dielectric loss test results. The device is equipped with the oil drainage solenoid switch, and we can empty the test cell without removing it and rinse it with the test sample oil.
● The instrument adopts the medium frequency induction heating, PID temperature control algorithm. This heating method has the advantages of non-contact between the test cell and the heating body, uniform heating, fast speed, convenient control, and strictly control of the temperature within error range of the preset temperature.
● Internal standard capacitor is SF6 gas-filled three-electrode capacitance, and its capacitor dielectric loss and electrical capacity are not affected by ambient temperature, humidity etc, so that the instrument accuracy can be ensured even after prolonged use.
● AC test power supply uses AC-DC-AC conversion, which effectively prevents the fluctuations in mains voltage and frequency from affecting the dielectric loss measurement accuracy. Even a generator, the instrument can work properly.
● Perfect protection function.When there is over voltage,over current or high-voltage short circuit, instruments can quickly cut off pressure, and issues a warning message. When the temperature of the sensor failure or not connected, the instrument will also issue a warning message.
● There is a temperature limiting relay in the medium frequency induction heating furnace. When temperature above 120 degrees, the instrument frees the relay and stops heating.
● Convenient test parameter setting.Temperature setting range 0~125 degree, AC voltage setting range 500~2200V, DC voltage setting range 0~500V.
● Using of large-screen LCD display, with backlight and clear display. Friendly interface, simply follow the Chinese menu prompt, enter the command, the instrument can be automatically tested. And automatically store and print test results.
● Built-in real-time clock, the test date and time may be saved, displayed and printed with the test results.
● Calibration functions of cleaned dry cell. The measurement of dry cell’s capacitance and dielectric loss factor can determine its cleaning and assembly conditions. The calibration data is automatically saved and so that it facilitates the calculation of relative permittivity and DC resistivity.

Specifications

Voltage supply 

AC 220V±10%

Power frequency 

50Hz/60Hz ±1%

Measuring range

Capacitance: 5pF~200pF
Relative Permittivity:1.000~30.000
Dielectric loss factor: 0.00001~100
DC Resistivity : 2.5MΩm~20TΩm

Measuring accuracy

Capacitance : ± (1% of reading+0.5pF)
Relative Permittivity: ±1% of  reading
Dielectric dissipation factor: ± (1% of  reading+0.0001)
DC Resistivity: ±10% of reading

Resolution

Capacitance: 0.01pF
Relative capacitivity: 0.001
Dielectric dissipation factor: 0.00001

Measured temperature range

0~125 degree

Temperature measurement error

±0.5 degree

AC Test Voltage (RMS) 

500~2200V Continuously adjustable, frequency 50Hz

Test Voltage DC

0~500V Continuously adjustable

Power consumption 

100W

Ambient temperature

0~40 degree

Relative humidity(RH)

<75%

Dimensions

500×360×420

Total weight 

22Kg

 

Product Pictures

GD6100C Transformer Insulation Oil Tan Delta Tester Oil Dielectric Tester6
GD6100C Transformer Insulation Oil Tan Delta Tester Oil Dielectric Tester5
GD6100C Transformer Insulation Oil Tan Delta Tester Oil Dielectric Tester4
GD6100C Transformer Insulation Oil Tan Delta Tester Oil Dielectric Tester7

Company Information

GD6100C Transformer Insulation Oil Tan Delta Tester Oil Dielectric Tester8
GD6100C Transformer Insulation Oil Tan Delta Tester Oil Dielectric Tester9
GD6100C Transformer Insulation Oil Tan Delta Tester Oil Dielectric Tester10
GD6100C Transformer Insulation Oil Tan Delta Tester Oil Dielectric Tester11


Product detail pictures:

OEM Best High Voltage Pulse Generator Factory –  GD6100C Transformer Insulation Oil Tan Delta Tester/Oil Dielectric Tester – HV Hipot detail pictures

OEM Best High Voltage Pulse Generator Factory –  GD6100C Transformer Insulation Oil Tan Delta Tester/Oil Dielectric Tester – HV Hipot detail pictures

OEM Best High Voltage Pulse Generator Factory –  GD6100C Transformer Insulation Oil Tan Delta Tester/Oil Dielectric Tester – HV Hipot detail pictures

OEM Best High Voltage Pulse Generator Factory –  GD6100C Transformer Insulation Oil Tan Delta Tester/Oil Dielectric Tester – HV Hipot detail pictures

OEM Best High Voltage Pulse Generator Factory –  GD6100C Transformer Insulation Oil Tan Delta Tester/Oil Dielectric Tester – HV Hipot detail pictures


Related Product Guide:

We always stick to the principle "Quality First, Prestige Supreme". We are fully committed to providing our clients with competitively priced quality products, prompt delivery and professional service for OEM Best High Voltage Pulse Generator Factory – GD6100C Transformer Insulation Oil Tan Delta Tester/Oil Dielectric Tester – HV Hipot , The product will supply to all over the world, such as: UAE, Cannes, Tajikistan, We are fully aware of our customer's needs. We provide high quality products, competitive prices and the first class service. We would like to establish good business relationships as well as friendship with you in the near future.
  • The company leader recept us warmly, through a meticulous and thorough discussion, we signed a purchase order. Hope to cooperate smoothly
    5 Stars By Carol from Ukraine - 2018.12.25 12:43
    The company's products can meet our diverse needs, and the price is cheap, the most important is that the quality is also very nice.
    5 Stars By Henry from Kazakhstan - 2017.10.13 10:47

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us