OEM Best Hipot Test Of Cable Factories – AC DC High Voltage Divider – HV Hipot
OEM Best Hipot Test Of Cable Factories – AC DC High Voltage Divider – HV Hipot Detail:
GDFR-C1 series AC/DC Voltage Meter
GDFR-C1 series AC/DC digital meter is on-site instrument, which test both AC and DC voltage. It consists of voltage divider and measurement instrument.
Features
● Balance type equal potential shield structure.
● Fully-sealed insulation cylinder with internal excellent components.
● High accuracy and linearity, good stability and anti-interference ability.
● The voltage ratio can be customized, suitable for calibration.
● Upside down is forbidden when installation.
Technical Specifications
Model No. | GDFR-C1-50 | GDFR-C1-100 | GDFR-C1-150 | GDFR-C1-200 | GDFR-C1-300 | GDFR-C1-400 |
Voltage(kV) | 50 | 100 | 150 | 200 | 300 | 400 |
DC frequency (Hz) | <2 | |||||
AC frequency (Hz) | 30-300 | |||||
Accuracy | AC: 1.5%/DC: 1.0% | |||||
Accuracy for option (G type) | AC: 1.0%/DC: 0.5% | – | ||||
Accuracy for option (H type) | AC: 0.5%/DC: 0.5% | – | – | |||
Impedance (MΩ) |
650 | 1280 | 2000 | 2640 | 4000 | 5360 |
Capacitance (pF) |
320 | 250 | 400 / 160 | 300 | 200 | 300 |
Voltage ratio | 1000:1 or 10000:1(or customized) | |||||
Dimension (mm) |
150×150 | 160×160 | 350×350 | 800×800 | 1000×1000 | |
Cable impedance(Ω) | 50 / 75 | |||||
Range | 1. Low range: 0-20kV 2. High range: 20kV-rated voltage 3. Low range: 0-200kV 4. High range:200kV-rated voltage |
|||||
Cable length(m) | 3 | 4 | 6 | 6 | 10 | 10 |
Weight(kg) | 5.5 | 9.5 | 12.5 | 14.5 | 27 | 40 |
Packing Medium | Polyurethane foaming agent | |||||
Operation temperature | 0℃-45℃ | |||||
Relative humidity | <85%RH, no condensation | |||||
Altitude | <1500m (or customized) | |||||
Use condition | Indoor use or outdoor use in Sunny day |
Product detail pictures:



Related Product Guide:
Our advantages are reduced prices,dynamic product sales workforce,specialized QC,solid factories,superior quality services for OEM Best Hipot Test Of Cable Factories – AC DC High Voltage Divider – HV Hipot , The product will supply to all over the world, such as: Bahrain, Guyana, Wellington, We have our own registered brand and our company is developing rapidly owing to high quality products, competitive price and excellent service. We sincerely hope to establish business relations with more friends from home and abroad in the near future. We look forward to your correspondence.

The customer service staff is very patient and has a positive and progressive attitude to our interest, so that we can have a comprehensive understanding of the product and finally we reached an agreement, thanks!

Send your message to us:
Write your message here and send it to us