OEM Best insulation tester megger price Supplier – GDF-3000 DC System Earth Fault Detector – HV Hipot

OEM Best insulation tester megger price Supplier – GDF-3000 DC System Earth Fault Detector – HV Hipot

Brief Description:


Product Detail

Product Tags

Related Video

Feedback (2)

We have now a hugely efficient team to deal with inquiries from buyers. Our goal is "100% client gratification by our solution high-quality, rate & our team service" and take pleasure in a great popularity among clients. With several factories, we will provide a wide assortment of Tan Delta Value, Capacitance And Dissipation Factor Test, Hipot Vlf, As a key enterprise of this industry, our corporation makes attempts to become a leading supplier, depending on the faith of expert excellent & throughout the world assistance.
OEM Best insulation tester megger price Supplier – GDF-3000 DC System Earth Fault Detector – HV Hipot Detail:

General Information

In DC system, there are many earth faults including indirect earth fault, non-metal earth fault, loop earth fault, positive and negative earthing fault, positive and negative balance earth fault, multi-point earth fault. GDF-3000 Earth Fault Tester for DC System locates these earth faults and displays the parameters of system voltage, earth voltage, earth resistance and earth impedance of branches accurately.

Functions

● System ground voltage measurement function, the instrument can measure the system ground voltage, negative to ground voltage, system voltage, can achieve 0-300V voltage monitoring range.
● System insulation impedance measurement function, the instrument can measure the positive to ground insulation impedance and the negative to ground insulation impedance of the system. It can realize the measurement of 0-999KΩ.
● AC string electrical detection function, the instrument can judge the AC string electrical failure in the DC system, and can measure the AC voltage value that enters in the DC system, the AC voltage measurement range is 0-280V.
● Branch insulation impedance measurement function. The instrument measures the positive and negative ground insulation impedance of each branch.
● Branch grounding fault point positioning function, the instrument can achieve the grounding fault point positioning function of the branch grounding fault.
● Ammeter function, the device can be used as a high-precision ammeter, and the current measurement resolution can reach 0.01mA.
● With a non-signal ground search function, the device can locate the ground fault point without injecting any signal into the system.
● Direction display function, for testing the branch with ground indication, the instrument will have a direction indication arrow to indicate the relative direction between the user’s grounding point and the found grounding point, to improve the search efficiency.
● Insulation index analysis function, when using the grounding function detection, after detecting a branch, the detector will display the insulation index of the branch for user reference and analysis.
● The waveform curve display function, when using the detector to detect the insulation condition of the tested branch, the display will display the current change of the measured branch in the form of a waveform curve, which is convenient for the user to quickly and accurately find the fault point.

Features

● The imported 16-bit microcontroller is used as the main system. The hardware design is strictly in accordance with the relevant standards of power and electromagnetic compatibility. Multiple redundancy methods are adopted internally to ensure the reliability of the device and the device under test.
● The high-precision DC clamp meter is used as the signal acquisition unit, and the voltage sampling adopts high-precision analog-to-digital conversion chip, and the voltage and impedance are accurately measured.
● LCD display, with friendly interface, clear and easy operation. Display insulation index vividly and real-time display waveform. It reflects insulation level of every branches and earth fault direction.
● Intelligent detection and recognition system.
● The “analyzer” can automatically identify the voltage level of the system, and display the information of the insulation impedance quickly when the insulation impedance of the system changes.
● After the detector is synchronized with the analyzer information, it is not affected by the detection distance;
● When the “detector” is inspecting, the clamp can clamp a single power cord, or clamp multiple power cords to improve detection efficiency;
● After the “detector” test is completed, if the tested branch has an insulation fault, the direction information of the fault point relative to the test point is determined.
● The wireless data transmission module is built in between the “analyzer” and the “detector” for communication, and the test function and display information are complete, and can deal with various insulation fault conditions in the DC system.
● The device can locate the grounding fault point without injecting signal into the DC system. In the signal mode, the device has a current limiting and voltage limiting module, which has no effect on the DC system.

Technical Specifications

Use Environment
Ambient temperature -30 ° C ~ +50 ° C;
Relative humidity ≤95%;
Wireless communication technical indicators
Signal power ≤ 10dbm;
Signal band 433Mhz;
Sensitivity -106dBm;
Transmission distance in the case of line-of-sight, reliable transmission distance of 250 meters from the ground 2 meters
Analyzer technical indicators
Applicable DC system voltage level 24V (customized), 48V, 110V, 220V or user-specified voltage level
System positive and negative voltage measurement range 0-300V
DC voltage measurement range to ground 0-300V
AC series power failure alarm threshold 5V
Voltage measurement resolution 0.1V
System ground resistance measurement range 0—999.9KΩ
Grounding resistance measurement resolution 0.1KΩ
Display mode LCD
Detection signal current size 0-2mA adjustable
Detection signal voltage amplitude 0-50V adjustable
Signal frequency no signal mode and 0.16Hz optional
DC-resistant system distributed capacitance interference 1000uF
Detector technical indicators
Insulation resistance detection range of branch circuit in signal mode
System voltage rating is 220V 0 -600KΩ
System voltage rating is 110V 0 -300KΩ
System voltage rating is 48V 0 -60KΩ
System voltage rating is 24V 0 -20KΩ
Insulation resistance measurement resolution 0.1KΩ
Insulation resistance detection range of branch circuit in no signal mode
System voltage rating is 220V 0 -50KΩ
System voltage rating is 110V 0 -25KΩ
System voltage rating is 48V 0 -10KΩ
System voltage rating is 24V 0 -5KΩ
Insulation resistance measurement resolution 0.1KΩ
Waveform display time 12 seconds
Current measurement range ±100mA
Current measurement resolution 0.01mA
Display mode LCD
Direction display mode same or opposite direction
Anti-DC system branch distribution capacitance interference 100uF
Distance to use with the analyzer no distance limit
Jaw size Diameter 30mm

Accessories

Detector 1 pc
Analyzer 1 pc
Adapter 2 pcs
Current clamp 1 pc
Test Lead(with crocodile clamp) 1 pc
Carry case 1 pc
User’s Guide 1 pc
Factory Test Report 1 pc

Product detail pictures:

OEM Best insulation tester megger price Supplier –  GDF-3000 DC System Earth Fault Detector – HV Hipot detail pictures


Related Product Guide:

We thinks what clients think, the urgency of urgency to act from the interests of a purchaser position of principle, allowing for greater top quality, decrease processing costs, price ranges are much more reasonable, won the new and aged prospects the support and affirmation for OEM Best insulation tester megger price Supplier – GDF-3000 DC System Earth Fault Detector – HV Hipot , The product will supply to all over the world, such as: kazan, Toronto, Kuwait, Our qualified engineering team will usually be prepared to serve you for consultation and feedback. We are able to also deliver you with absolutely free samples to meet your needs. Best efforts might be made to offer you the ideal service and products. For anyone who is interested in our company and items, please make contact with us by sending us emails or contact us right away. In order to know our solutions and organization. ar more, you can come to our factory to determine it. We are going to usually welcome guests from around the globe to our corporation. o create small business relations with us. Please really feel no cost to speak to us for enterprise. nd we believe we are going to share the most effective trading practical experience with all our merchants.
  • Product quality is good, quality assurance system is complete, every link can inquire and solve the problem timely!
    5 Stars By Bertha from Amman - 2017.06.29 18:55
    This supplier's raw material quality is stable and reliable, has always been in accordance with the requirements of our company to provide the goods that quality meet our requirements.
    5 Stars By Hazel from Surabaya - 2018.09.23 17:37

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us