OEM Best Loop Resistance Tester Manufacturer – GDSL-D Seriese Digital Primary Current Injection Test Set – HV Hipot
OEM Best Loop Resistance Tester Manufacturer – GDSL-D Seriese Digital Primary Current Injection Test Set – HV Hipot Detail:
Adoption of Standard
● DL/T 596-2005 “Procedure Test Procedures for Electrical Equipment”
● GB1094.1-GB1094.6-96 “Shell protection level”
● GB2900 “Electrical Terminology”
● GB/T16927.1~2-1997 “High Voltage Test Technology”
● GB4793-1984 “Safety Requirements for Electronic Measuring Instruments”
● GB191 “Package Storage and Transportation Mark”
● GB/T.311-1997 “Insulation and coordination of high voltage power transmission and transformation equipment”
Features
● Using high conductivity copper as the output electrode, the contact surface is large and the flow capacity is strong.
● Brushed aluminum plate with a new process, simple and eye-catching, wear-resistant and pollution-resistant.
● The all-metal spray plastic case and the internationally popular camel gray tone are solid and reliable, ensuring the reliability of logistics.
● The use of brake universal casters makes movement and fixing more flexible and convenient.
● Wedge-shaped airflow duct to improve heat dissipation and greatly extend service life.
● The whole machine is small in size and light in weight, which is very suitable for field use.
Functions
● It has zero protection function to prevent the impact of large current from causing damage to the sample. It cannot be started when it is not at zero position.
● Impact selection function, when the circuit breaker quick-break test is performed, the zero protection function can be cut off and the required current value can be directly output.
● Output current mode: The true RMS value is continuously adjustable.
● The output current is a standard sine wave, and the waveform distortion rate is less than 5%.
● Voltage and current display adopts new high-precision LED digital display
● Switchable size current range to improve display fineness for more accurate readings.
● The power supply voltage and regulator output voltage can be switched to display for easy viewing.
● The equipment capacity is designed for short-term, intermittent work in 5 minutes.
● For batch testing, close for 10 minutes after 2.5 minutes of continuous operation.
● It can measure the current action time of the tested component and record the lock action time synchronously. (optional)
● Measured time range: 0.001S~999.999S Resolution 1ms, measurement error: 0.005% range ± 2digs. (optional)
● The test value of primary current and secondary current can be directly displayed to facilitate the transformer ratio test. (optional)
● Secondary current range 0~5A resolution 1mA (optional)
● If the temperature rise (30 minutes – 24 hours) should be customized according to the long-term work temperature rise. (optional)
● Can be customized three-phase with balance adjustment riser (optional)
● Can be customized AC and DC riser (optional)
Specifications
Model | Output capacity (kVA) | Output current (A) | Power Supply (V) | Open circuit voltage (V) | Power phase | Mark | |
GDSL-D-500 | 3 | 500 | 220 | 6 | LN | Integrated | |
GDSL-D-1000 | 6 | 1000 | 220 | 6 | LN | Integrated | |
GDSL-D-1500 | 9 | 1500 | 220 | 6 | LN | Integrated | |
GDSL-D-2000 | 12 | 2000 | 220 or 380 | 6 | LN | AB | Integrated or combination |
GDSL-D-2500 | 15 | 2500 | 220 or 380 | 6 | LN | AB | Integrated or combination |
GDSL-D-3000 | 18 | 3000 | 220 or 380 | 6 | AB | Integrated or combination | |
GDSL-D-4000 | 24 | 4000 | 380 | 6 | AB | combination | |
GDSL-D-5000 | 30 | 5000 | 380 | 6 | AB | combination | |
GDSL-D-6000 | 36 | 6000 | 380 | 6 | AB | combination | |
GDSL-D-8000 | 48 | 8000 | 380 | 6 | AB | combination | |
GDSL-D-10000 | 60 | 10000 | 380 | 6 | AB | combination | |
GDSL-D-12000 | 72 | 12000 | 380 | 6 | AB | combination | |
GDSL-D-15000 | 90 | 15000 | 380 | 6 | AB | combination | |
Can be customized due to customer;s special requirements |
Accessories
Primary current injection test set | 1 piece |
Power cord | 1 piece |
Grounding Wire | 1 piece |
High Current line(standard 2m) | 2 piece |
Certificate | 1 copy |
Manual | 1 copy |
Packing list | 1 copy |
Test Report | 1 copy |
Product detail pictures:







Related Product Guide:
We regularly perform our spirit of ''Innovation bringing progress, Highly-quality making certain subsistence, Administration marketing benefit, Credit score attracting customers for OEM Best Loop Resistance Tester Manufacturer – GDSL-D Seriese Digital Primary Current Injection Test Set – HV Hipot , The product will supply to all over the world, such as: Cape Town, Auckland, Spain, Adhering to the principle of "Enterprising and Truth-Seeking, Preciseness and Unity", with technology as the core, our company continues to innovate, dedicated to providing you with the highest cost-effective solutions and meticulous after-sales service. We firmly believe that: we're outstanding as we have been specialized.

Factory equipment is advanced in the industry and the product is fine workmanship, moreover the price is very cheap, value for money!
