OEM Best megger Exporters – GDHX-9500 Phase Detector – HV Hipot
OEM Best megger Exporters – GDHX-9500 Phase Detector – HV Hipot Detail:
General Information
GDHX-9500 Phase Detector is mainly used in electric power lines, phase and phase sequence calibration in substation, with main functions including electrical inspection, phase calibration and phase sequence measurement. It uses double shielding and brand new digital circuits, with strong anti-interference, accorded with EMC standards, suitable for various electromagnetic interference situations.
The high voltage phase signal of measured lead will be transmitted directly after treatment, the handset will receive and make phase comparison, determine the results after phase detection, real-time display phase angle difference and vector.It uses wireless transmission technology, safe and reliable, fast and accurate, suitable for using at different voltage levels (6V-500KV). When checking the grid structure, it is able to accurately identify the relative phase of different leads for the three-phase connected line, without any electrical connection between two measurement components, which makes the application of the measurement device very flexible and safe.
Security Matters
● Using wireless transmission technology, its basic working principle is real-time phase comparison.
● Please observe and follow the regulation to use this product, in order to ensure the safe operation of the instrument, the ends of X and Y detector are not allowed to make withstand voltage test.
● The metal head parts of the insulating rod is strictly prohibited to contact with any objects during the test.
● Please comply with the national power industry safety regulations of preventive test for safety tools and products.
● Please pay attention to the training and examination for staffs who work on high-voltage live lines or near the high-voltage lines.
● Phase calibration on live equipment must be carried out by insulating rod.
Note: The safe usage length and test standards of insulating rod for “Wireless Phase Detector”.
(Excerpting from “Electrical safety working regulations of State Grid Corporation”.)
1. Safety distance between staff and the charged body during live operation.
|
Voltage Level |
10kV |
35kV |
66kV |
110kV |
220kV |
330kV |
500kV |
|
Safety Distance |
0.4M |
0.6M |
0.7M |
1.0M |
1.8M |
2.2M |
3.4M |
2. The minimum effective insulation length of insulating rod during live operation.
|
Voltage Level |
10kV |
35kV |
66kV |
110kV |
220kV |
330kV |
500kV |
|
Min. effective insulation length |
0.7M |
0.9M |
1.0M |
1.3M |
2.1M |
3.1M |
4.0M |
Note: The test standard of insulating tools checking test (subsection): applying power frequency 75kV each 300mm for 1min, if no breakdown, no flashover and over-heat, it is considered as qualify.
Features
● Test voltage: 10V-500kV, suitable for different voltage level.
● Accuracy: self-calibrating error ≤±3°.
● Sampling speed: 10 times/s.
● Date and time setting: date and time adjustment, easy for users to browse, view the historical data.
● Back-light time setting: normally on, normally off, 0-999s can be set by user.
● Auto power off setting: 0-999mins can be set by user.
● In-phase: ≤20° is considered as in-phase (phase threshold within 0-90°, can be set by user. The system default is 20°.)
● Out-phase qualitative: >20° (phase threshold within 0-90°, can be set by user. The system default is 20°.)
● Field calibration function: on-site calibration for measured lead, ensure the accuracy of phase angle.
● Transmission distance between handset and X, Y detector: X≤150m, Y≤150m.
● Multiple mode design, with strong applicability, safer and more convenient.
● Unique human-computer interaction interface, simple operation.
● FCC antenna design, the signal is stronger and easier to penetrate the blocking of wall, door, or barrier.
● Double shielding, strong an-ti interference, in full accordance with EMC standards.
● Charts and data display, more convenient and easier to read.
● Qualitative measurement, display by sound and light signal.
● Quantitative measurement, real-time display phase angle difference, error≤5°.
● Phase sequence calibration, positive phase sequence, negative phase sequence (120°, 240°).
Specifications
|
Test voltage |
10V-500kV |
|
Power supply |
Handset: No.5 AA alkaline battery 2 sections (1.5V) |
|
X and Y detector: No.7 AA alkaline battery 2 sections (1.5V) |
|
|
Wireless transmission distance |
Visual distance 150m |
|
In-phase |
Phase angle deviation≤20° (threshold within 0-90°, can be set by user self. ) |
|
Out-phase |
Phase angle deviation>20° (threshold within 0-90°, can be set by user self. ) |
|
Display accuracy |
Quantitative measurement≤3° |
|
Phase angle resolution |
1° |
|
Phase sequence measurement |
Through 120° clockwise/240°anti-clockwise to determine and indicate phase sequence |
|
Display |
Positive display LCD, clearly display under the sunshine |
|
Operation temperature |
-35℃-+50℃ |
|
Storage temperature |
-40℃-+55℃ |
|
Relative humidity |
≤95% RH, Non-condensate |
|
Handset |
0.31kg |
|
X detector |
0.13kg |
|
Y detector |
0.13kg |
Product detail pictures:
Related Product Guide:
As for competitive selling prices, we believe that you will be searching far and wide for anything that can beat us. We will state with absolute certainty that for such excellent at such charges we are the lowest around for OEM Best megger Exporters – GDHX-9500 Phase Detector – HV Hipot , The product will supply to all over the world, such as: Spain, Turkey, Victoria, "Good quality, Good service " is always our tenet and credo. We take every effort to control the quality, package, labels etc and our QC will check every detail during producing and before shipment. We have been willing to establish long business relationship with all those who seek the high quality products and good service. We've got set up a wide sales network across European countries, North of America, South of America, Middle East, Africa, East Asia countries.Please contact us now, you will find our expert experience and high quality grades will contribute to your business.
This is a honest and trustworthy company, technology and equipment are very advanced and the prodduct is very adequate, there is no worry in the suppliment.





