OEM Best numerical relay testing Supplier – GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot
OEM Best numerical relay testing Supplier – GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot Detail:
Features
A. Working conditions
1. Power supply: AC 220V±10%,50Hz
2. Working environment: Temperature -10℃~40℃; Humidity: ≤85%
3. Atmosphere: 86-106kPa
B. Output power supply
1. AC voltage: 0-220V/3A Adjustable
2. AC current: 0-100A/7V (200A can be customized); 0-20A/25V Adjustable; 0-5A/5V Adjustable
3. DC voltage: 0-220V/3A Adjustable
4. DC current:0-20A/25V
5. Fixed voltage output: DC 24V/48V/110V/220V
6. Current/Voltage accuracy: ±1%.
C. Performance Index
1. Ammeter and voltmeter: 41/2 digit.
2. Digital millisecond meter: 0-99.9999s(999.999s can be customized) Resolution: 0.1ms.
D. Functions
1. Measure relay: Measure start value, return value and drop-off to pick-up ratio of current, voltage relay.
2. Time relay: Measure start value, return value and action time.
3. Intermediate relay: Measure all kinds of coil with start. Remain start value, return value, holding value and action time of coil intermediate relay.
4. Reclosing relay: Charge test of capacitance, charge time, reclosing time and middle components test.
5. Differential relay: DC Excitation test, Braking test, Volt-ampere characteristic test.
6. Other common relays and LV circuit breaker.
Accessories
Name | Qty |
GDJB-II secondary injection test set | 1 pc |
Power cable | 1 pc |
Test line | 6 pcs |
Current line | 2 pcs |
Fuse | 4 pcs |
Manual | 1 copy |
Certificate | 1 copy |
Product detail pictures:







Related Product Guide:
As for aggressive price ranges, we believe that you will be searching far and wide for anything that can beat us. We can easily state with absolute certainty that for such high-quality at such price ranges we're the lowest around for OEM Best numerical relay testing Supplier – GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot , The product will supply to all over the world, such as: Milan, Sheffield, Macedonia, With a wide range, good quality, reasonable prices and stylish designs, our products are extensively used in this field and other industries. We welcome new and old customers from all walks of life to contact us for future business relationships and achieving mutual success! We welcome customers, business associations and friends from all parts of the world to contact us and seek cooperation for mutual benefits.

The customer service staff's answer is very meticulous, the most important is that the product quality is very good, and packaged carefully, shipped quickly!
