OEM Best Pure Wave Generator Exporters – GDOT-100D 100kV Insulation Oil Tester – HV Hipot
OEM Best Pure Wave Generator Exporters – GDOT-100D 100kV Insulation Oil Tester – HV Hipot Detail:
General Information
In power system, railway system and large petrochemical industrial enterprises all have a lot of electrical equipment, its internal insulation is mostly oil-filled insulation type.
Dielectric strength test for insulating oil is a routine test which shall be measured.
In order to meet the market needs. Our company self-developed and produced GDOT series dielectric strength tester for insulation oil according to national standard GB/T5072002, industrial standard DL429.991 and the latest electric power industry standard DL/T846.7- 2004.
The instrument use single chip microcomputer as the core, to achieve full automatic testing and high precision measurement, greatly improves the work efficiency and also reduce the labor intensity of the workers greatly.
Features
● With microprocessor, three cups in one, automatically complete boosting, holding, stirring, static releasing, calculation and printing.
● Enable to carry out oil circulating withstand voltage test in the range of 0-100KV.
● Large screen LCD display.
● Simple to operate, automatically complete 1-3 oil samples withstanding voltage test according to the settings. Each oil sample will be automatically stored for each breakdown voltage value and cycle number. After the test is completed, the thermal printer can print out the breakdown voltage value and average value of each oil sample.
● This series has strong applicability, not only can be used in laboratories, but also be used in outdoor fields. The instrument also has strong anti-interference ability and can work normally in strong electromagnetic field environment. It is very suitable for use in departments with more oil samples and tight test time.
● With over-voltage, over-current, zero return protective function, it can ensure the safety of operators and device at normal use.
● Increasing speed can be set according to different test standard.
Specifications
Output voltage |
0-100kV |
Power distortion rate |
<3% |
Voltage increasing speed |
2.0,2.5,3.0,3.5kV/s (adjustable) |
Voltage measurement error |
±3% |
Capacity |
1.5kVA |
Power input |
AC220V± 10%, 50Hz±1Hz |
Power |
<200W |
Working temperature |
0℃-+40℃ |
Oil cup volume |
200mL (400mL optional) |
Electrode spacing |
2.5mm |
Humidity |
<80%RH |
Dimension |
470*430*480mm |
Weight |
49 kg |
Product detail pictures:
Related Product Guide:
High quality Very first,and Shopper Supreme is our guideline to offer the most beneficial company to our clients.Nowadays, we're hoping our best to be certainly one of the top exporters in our area to satisfy consumers additional will need for OEM Best Pure Wave Generator Exporters – GDOT-100D 100kV Insulation Oil Tester – HV Hipot , The product will supply to all over the world, such as: Argentina, Serbia, United Kingdom, High output volume, top quality, timely delivery and your satisfaction are guaranteed. We welcome all inquiries and comments. If you are interested in any of our products or have an OEM order to fulfill, please feel free to contact us now. Working with us will save you money and time.
By Monica from European - 2017.08.18 11:04
A nice supplier in this industry, after a detail and careful discussion, we reached a consensus agreement. Hope that we cooperate smoothly.
By Victoria from Liverpool - 2018.06.05 13:10