OEM Best relay tester made in china Suppliers – GDJB-1200A Six Phase Relay Protection Test Set – HV Hipot

OEM Best relay tester made in china Suppliers – GDJB-1200A Six Phase Relay Protection Test Set – HV Hipot

Brief Description:


Product Detail

Product Tags

Related Video

Feedback (2)

All we do is often involved with our tenet " Purchaser to start with, Rely on initially, devoting over the food stuff packaging and environmental defense for Tan Delta Test Of Transformer Bushing, Delta Capacitor, Capacitor For Transformer, We focus on for making superb top quality goods to provide support for our purchasers to ascertain long-term win-win romantic relationship.
OEM Best relay tester made in china Suppliers – GDJB-1200A Six Phase Relay Protection Test Set – HV Hipot Detail:

Features

● Output up to 6-phase voltage 6-phase current, which can be combined to realize conventional 4-phase voltage 3-phase current type, 6-phase voltage type, 6-phase current type, and 12-phase output mode.

● High-performance embedded industrial control computer and 8.4-inch large-screen high-resolution color TFT liquid crystal display, which can provide rich and intuitive information, including the current working status of the device, next working tips and various help information;

● The output uses a high-fidelity, high-reliability modular linear power amplifier instead of a switch-type power amplifier for superior performance. It will not generate high and medium frequency interference to the test site, and it will ensure excellent waveform smoothing and accuracy from high current to small current.

● The output part is controlled by DSP, which has fast calculation speed, strong real-time digital signal processing capability, transmission bandwidth and high-resolution D/A conversion. The output waveform has high precision, small distortion and good linearity. It adopts a large number of advanced technologies and precision component materials, and has carried out professional structural design. Therefore, the device is small in size, light in weight, full in function, easy to carry, and can be operated once start up, and the test is very convenient.

● It can complete a large number of large-scale complex verification work with high degree of automation. It can easily test and scan various protection settings, perform fault playback, store test data in real time, display vector graphics, and print reports online.

● There is an independent 110V and 220V dedicated adjustable DC power output for on-site inspection.

● The new generation GDJB-1200A tester is equipped with 10-way opening and 8-way opening, which is convenient for self-injection test. The input contact is compatible with an empty contact and 0~250V potential contacts, which can be intelligently and automatically recognized.

● Can perform a variety of complex calibration tasks, and can easily test and scan various protection settings for fault playback. Store test data in real time, display vector graphics, print reports, etc.

● The heat dissipation structure is designed reasonably, the hardware protection measures are reliable and perfect, and the power soft start function, software self-diagnosis and output blocking function are provided.

Specifications

AC Current Output
 
6-phase (RMS) 6*0~30A
3-phase (RMS) 3*0~60A
6-phase parallel current output (RMS) 0~180A
Allowable long time working value of phase current (RMS) 10A
Maximum output power of phase current 400VA
Allowable working hours @ max. output of 6-phase parallel current 10s
Accuracy ≤0.5A   ±2mA
>0.5A   0.2%
Frequency range (Fundamental wave) 0~1000Hz
Harmonic times 0~20 times
DC Current Output
 
Current output 0~±10A/phase;  0~±60A/6-pahse parallel
Accuracy  0.5%
Maximum output load voltage 20V
AC Voltage Output
 
Phase voltage output (RMS) 0~120V   Accuracy: 0.2%
Line voltage output (RMS) 0~240V
Phase voltage/Line voltage output power 80VA/100VA
Frequency range (Fundamental wave) 0~1000Hz
Harmonic times 1~20 times
DC Voltage Output
 
Phase voltage output amplitude 0~±160V    Accuracy: 0.5%
Line voltage output amplitude 0~±320V
Phase voltage/Line voltage output power 70VA/140VA
Binary
 
Binary input 10 channels
Idle contact 1~20mA, 24V
Potential contact access “0″: 0 ~+6V; “1″: +11 V ~+250 V
Binary output  8 pairs   DC: 220 V/0.2 A; AC: 220 V/0.5 A
Time Measuring Range  0.1ms~9999s        Measuring accuracy: <0.1mS
Dimension & Weight 480*360*200mm³       19kg 

Accessories

No.

Name

Description

Qty/Unit

Picture

1

Main Unit

GDJB-1200A

1set

GDJB-1200A Six Phase Relay Protection Test Set01

2

Fuse

2A

4 pieces

GDJB-1200A Six Phase Relay Protection Test Set010

10A

4 pieces

3

Power cord

 

1 piece

GDJB-1200A Six Phase Relay Protection Test Set09

4

Test wire

0.5m(red,yellow,green,black each 2 piece)

8 pieces

GDJB-1200A Six Phase Relay Protection Test Set08

5

Test wire 4 core

Black(red,yellow,green,black)-flat

2 pieces

GDJB-1200A Six Phase Relay Protection Test Set07

6

Test wire 4 core

Black(red,yellow,green,black)-circular

2 pieces

GDJB-1200A Six Phase Relay Protection Test Set06

7

Test wire

blue

1 piece

GDJB-1200A Six Phase Relay Protection Test Set05

8

Test wire

(white,coffee each 1 piece)

2 pieces

9

Test wire

red, green, yellow each 1 piece)

3 pieces

10

Test wire

black

2 pieces

11

Communication wire

 

1 piece

GDJB-1200A Six Phase Relay Protection Test Set04

14

Large test clamp

(red,yellow,green,black each 1 piece)

4 pieces

GDJB-1200A Six Phase Relay Protection Test Set03

15

Small test clamp

(yellow,green, each 4 pieces)

8 pieces

16

Small test clamp

(red,black each 5piece)

10 pieces

17

Illustration

(red,yellow,green,black each 2 pieces)

8 pieces

18

Test needle

(red,yellow,green,black each 3 pieces)

12 pieces

19

CD

 

1 copy

GDJB-1200A Six Phase Relay Protection Test Set02

20

QC pass

In English

1 copy

GDJB-1200A Six Phase Relay Protection Test Set011

21

Manual

In English

1 copy

GDJB-1200A Six Phase Relay Protection Test Set012

Product detail pictures:

OEM Best relay tester made in china Suppliers –  GDJB-1200A Six Phase Relay Protection Test Set – HV Hipot detail pictures

OEM Best relay tester made in china Suppliers –  GDJB-1200A Six Phase Relay Protection Test Set – HV Hipot detail pictures

OEM Best relay tester made in china Suppliers –  GDJB-1200A Six Phase Relay Protection Test Set – HV Hipot detail pictures

OEM Best relay tester made in china Suppliers –  GDJB-1200A Six Phase Relay Protection Test Set – HV Hipot detail pictures

OEM Best relay tester made in china Suppliers –  GDJB-1200A Six Phase Relay Protection Test Set – HV Hipot detail pictures

OEM Best relay tester made in china Suppliers –  GDJB-1200A Six Phase Relay Protection Test Set – HV Hipot detail pictures


Related Product Guide:

To be the stage of realizing dreams of our employees! To build a happier, more united and more professional team! To reach a mutual benefit of our customers, suppliers, the society and ourselves for OEM Best relay tester made in china Suppliers – GDJB-1200A Six Phase Relay Protection Test Set – HV Hipot , The product will supply to all over the world, such as: Myanmar, UK, Lithuania, Insisting over the high-quality generation line management and prospects guide provider, we've made our resolution to offer our shoppers using the initially stage purchasing and soon after provider working experience. Preserving the prevailing helpful relations with our prospects, we even now innovate our product lists the many time to meet up with the brand new wants and stick to the latest trend of this business in Ahmedabad. We're ready to facial area the difficulties and make the transform to grasp many of the possibilities in international trade.
  • Good quality, reasonable prices, rich variety and perfect after-sales service, it's nice!
    5 Stars By Princess from Australia - 2017.02.18 15:54
    Perfect services, quality products and competitive prices, we have work many times, every time is delighted, wish continue to maintain!
    5 Stars By Elsie from Jersey - 2018.09.21 11:01

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us