With a sound business credit, excellent after-sales service and modern manufacturing facilities, we have earned an excellent reputation among our customers across the world for Capacitance Can Be Measured By, Transformer Oil Bdv Test, Vlf Test Kit, At present, company name has more than 4000 kinds of products and gained good reputation and big shares on market domestic and overseas.
OEM Best soil resistivity measurement Factory – Substation Temperature Monitoring System – HV Hipot Detail:

General Information

There are usually two ways to monitor the insulation condition of high voltage electrical equipment in substations: online monitoring and live (portable) online detection. The former one can obtain the characteristic parameters reflecting the abnormal insulation of the equipment at any time, which is convenient for automatic management. However, the investment is relatively large, the installation and construction are relatively troublesome, and regular maintenance is needed. For the latter, it has the advantages of low investment, highly targeted, easy to install, maintain and update. As long as the sampling unit is installed in the electrical equipment in advance, a regular detection can be done for electrical equipment in operation, and insulation flaw can be found in time, so as to prolong the pretest period of power failure and completely replace on-line monitoring method.

GDDJ-HVC dielectric loss tester for live capacitive equipment can be used to measure dielectric loss and capacitance of capacitive equipment (bushing, CT, CVT, coupling capacitor), and detect insulation flaws effectively.

Features

1. External hole type current sensor with high precision is often used instead of the traditional sampling unit, which includes more than one switch circuit. During testing, multiple short tabs are needed to lead end shielding current to test instrument. GDDJ – HVC uses traditional straight-through structure, can be installed near the equipment, lead of end shielding is not broken and the length is very short, which avoid open circuit of end shielding. The sensor can accurately detect signals within 100μA~700mA. Impedance of sensor is low, can withstand power frequency current 10A and lightning impulse current 10kA, meet use conditions of online detection.

2. The sampling unit adopts die-casting aluminum shell sealing waterproof design, and adopts waterproof cable connector for secondary output, which is convenient for connection; After the sensor is installed, it is normally not energized. For testing, only the secondary cable of the sampling unit need be connected, and “plug and play” can be achieved without any operation on the end shielding signal cable.

3. The core processor of the instrument is American TI 32-bit floating-point high performance digital signal processor (DSP), which runs a real-time operating system and adopts an extended 16-bit, high-speed, multi-channel synchronous sampling analog digital converter (A/D) to realize real-time measurement and high-precision calculation of the monitored quantity. Able to monitor multiple devices simultaneously.

4. Two on-line detection methods for dielectric loss can be provided, which can measure dielectric loss difference and capacitance ratio of two capacitive devices in the same phase, and PT secondary voltage can be used as the reference signal to measure the capacitance and dielectric loss of the device. Using the compensating current sensor and advanced digital filtering technology, the problem of dielectric loss precision and stability is solved, combined with perfect electromagnetic shielding measures and advanced processing technology, digital filtering can ensure dielectric loss test results are not affected by the influence of harmonic interference and pulse interference, with absolute precision up to ±0.05%.

5. With the detection of dielectric loss difference and capacitance ratio of in-phase capacitive equipment, it can not only avoid the distortion of dielectric loss test result caused by using PT secondary voltage as the reference signal, but also help to reduce the influence of phase-to-phase electric field interference.

6. The detector is equipped with a large LCD screen for displaying the monitored voltage, current, dielectric loss, resistive current, capacitive current and other data.

7. The tester not only has the function of live detection, but also can monitor the equipment online for a long time, and automatically record the monitored data.

8. The system adopts external sensors instead of “traditional sampling unit”, which can be easily upgraded from “live detection” to “online monitoring” under normal operation of the equipment. There is no need to remove the installed sensors, no need to disable the device, just add a monitoring unit (IED).

9. The detector adopts portable design, simple to operate, the lithium battery in the machine can maintain 8 hours of continuous working time, fully meet the requirements of field use.

Specification

Main unit
Power supply Maintenance-free battery
Cable 30m, 2 pieces
Ambient temperature -45~60℃
Display Large screen LCD display, suitable for outdoor use.
Size 430*340*160mm
Weight 5kg
Measurement range & accuracy
Current Cx=100μA~1000mA, Cn=100μA~1000mAAccuracy: ±(0.5%+1digit)
Voltage Vn=3V~300V
Accuracy: ±(0.5%+1 digit)
Dielectric loss Tanδ= -200%~200%
Accuracy: ±0.05%
Capacitance ratio Cx: Cn=1:1000~1000:1
Accuracy: ±(0.5%C+1 digit)
 
Capacitance
Cx=10pF~0.3μF
Accuracy: ±(0.5%C+2pF)
Note: actual measurement accuracy is related with current of test object and accuracy of PT (or CVT) in use.
Resistive current Irp=10μA~200mA (peak)
Accuracy: ±(0.5%+1digit)
Capacitive current Icp=10μA~200mA
Accuracy: ±(0.5%+1digit)
Other characteristics
Harmonic suppression Waveform distortion of input current signal will not affect the measurement accuracy.
 Power management
 
When the battery power in the machine is low or has not been measured for a long time, it will give sound alarm and automatically shut down.
Charging time 12~24 hours in shutdown state, intelligent charging system, power-off protection after fully charge.

Product detail pictures:

OEM Best soil resistivity measurement Factory –  Substation Temperature Monitoring System – HV Hipot detail pictures


Related Product Guide:

To create much more price for clients is our company philosophy; purchaser growing is our working chase for OEM Best soil resistivity measurement Factory – Substation Temperature Monitoring System – HV Hipot , The product will supply to all over the world, such as: Philippines, Lebanon, Paraguay, We are looking forward to cooperating closely with you to our mutual benefits and top development. We guaranteed quality, if customers were not satisfied with the products' quality, you can return within 7days with their original states.
  • This company can be well to meet our needs on product quantity and delivery time, so we always choose them when we have procurement requirements.
    5 Stars By Christina from Lesotho - 2017.05.02 18:28
    The supplier abide the theory of "quality the basic, trust the first and management the advanced" so that they can ensure a reliable product quality and stable customers.
    5 Stars By Christopher Mabey from Jordan - 2018.10.01 14:14

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us