OEM Best Tensile testing machine Exporters – GDZL-503 Automatic Interfacial Tension tester – HV Hipot
OEM Best Tensile testing machine Exporters – GDZL-503 Automatic Interfacial Tension tester – HV Hipot Detail:
Intermolecular forces will generate interface tension and surface tension of liquids. The value of tension reflects liquid sample’s physics and chemical properties, which is one of the most important index for product quality.
GDZL-503 automatic interfacial tension tester tests kinds of liquid surface tension and interface tension according to ring method which is simple and accurate. It is widely used in electric, petroleum, chemical,medicine, food and teaching filed.
Features
● Exclusive and quick response electromagnetic balance sensor is adopted, to improve the accuracy of the measurement and degree of linearity.
● Only using one point calibration, to solve the problem of previous sensor which needs multi-point calibration. It is no need to use zero potentiometer and full scale potentiometer.
● Real-time show equivalent tension value and current weight.
● Integrated with temperature detection circuit, to compensate temperature automatically for test result.
● 240*128 dot matrix LCD screen.No logo button has function of screen protection.
● Save up to 255 history records with time indicated.
● Built in high speed thermal mini printer to print out quickly. It also has function of offline print.
● With RS232 port, to connect with PC directly.
Specification
Measuring range | 0-200mN/m |
Accuracy | 0.1% of the reading±0.1 mN/m |
Resolution | 0.1mN/m |
Sensitivity | 0.1mN/m |
Power supply | AC220V±20%,50Hz±10% |
Maximum power consumption | 20W |
Environmental temperature | 10~30℃(25℃ is the best) |
Environmental humidity | ≤85% RH |
Dimension | 200×300×330(mm) |
Weight | 6kg |
Product detail pictures:


Related Product Guide:
Normally customer-oriented, and it's our ultimate concentrate on for being not only one of the most dependable, trustable and honest supplier, but also the partner for our shoppers for OEM Best Tensile testing machine Exporters – GDZL-503 Automatic Interfacial Tension tester – HV Hipot , The product will supply to all over the world, such as: Burundi, Egypt, Kenya, We seriously promise that we provide all the customers with the best quality products, the most competitive prices and the most prompt delivery. We hope to win a resplendent future for customers and ourselves.

The factory technical staff gave us a lot of good advice in the cooperation process, this is very good, we are very grateful.
