OEM Best Testing A Capacitor With A Voltmeter Factory – GDZJ-30S Turn-to-Turn Surge Withstand Tester – HV Hipot

OEM Best Testing A Capacitor With A Voltmeter Factory – GDZJ-30S Turn-to-Turn Surge Withstand Tester – HV Hipot

Brief Description:


Product Detail

Product Tags

Related Video

Feedback (2)

"Sincerity, Innovation, Rigorousness, and Efficiency" will be the persistent conception of our company to the long-term to establish together with customers for mutual reciprocity and mutual gain for Tan Delta Kit, Tanedelta Electrical Testing, Electrical Pd, For further inquires please do not hesitate to contact us. Thank you - Your support continuously inspires us.
OEM Best Testing A Capacitor With A Voltmeter Factory – GDZJ-30S Turn-to-Turn Surge Withstand Tester – HV Hipot Detail:

General Information

GDZJ-30S Turn-to-Turn Surge Withstand Tester application

Specifications

Input voltage

220V±5%; frequency 50/60Hz±2%

Measurement range

0-30kV, continuous adjustment, ±5%

Trigger times

6.25 time/s - 50 times/s

Waveform rising time

0.1-0.5μS

Capacitance error

(+0.3) / (-0.1) µs

Impulse capacitance

0.01μF -0.1μF

Max output energy

60J

Power consumption

1000VA

Insulation resistance

Insulation resistance between power input terminal and tester ≥20MΩ

Dielectric strength

1500V/50Hz at 1min, there is no flashing and breakdown for withstand voltage test.

Temperature

0-40 degree

Relative humidity

≤80% at 40 degree

Waveform capacitance deviation

±3%

Dimension

650*550*1700mm

Weight

100kg

Application

Turn to turn withstand voltage test for rated voltage 10kV motor


Product detail pictures:

OEM Best Testing A Capacitor With A Voltmeter Factory –  GDZJ-30S Turn-to-Turn Surge Withstand Tester – HV Hipot detail pictures


Related Product Guide:

Our merchandise are broadly identified and trusted by end users and can satisfy continually developing economic and social requires for OEM Best Testing A Capacitor With A Voltmeter Factory – GDZJ-30S Turn-to-Turn Surge Withstand Tester – HV Hipot , The product will supply to all over the world, such as: Israel, Hongkong, Guinea, We will not only continuously introduce technical guidance of experts from both home and abroad, but also develop the new and advanced products constantly to satisfactorily meet the needs of our clients all over the world.
  • The company can keep up with the changes in this industry market, product updates fast and the price is cheap, this is our second cooperation, it's good.
    5 Stars By Chris Fountas from Detroit - 2018.11.04 10:32
    We have worked with many companies, but this time is the best,detailed explanation, timely delivery and quality qualified, nice!
    5 Stars By Anna from Egypt - 2018.11.28 16:25

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us