OEM Best testing of instrument transformer Factories – GDJF-2006 Partial Discharge Analyzer – HV Hipot
OEM Best testing of instrument transformer Factories – GDJF-2006 Partial Discharge Analyzer – HV Hipot Detail:
Features
● With high speed, big capacity data acquisition card. Continuously collect partial discharge data, good repeatability, and high accuracy.
● Functions of testing, analyzing (multi-parameter analysis, two-dimension atlas analysis, three-dimension atlas analysis), data storage, report, and print. Display waveform (ellipse, sine wave, line), discharge value and test voltage.
● Suitable for 50Hz, 150Hz frequency power supply, up to 400Hz. Automatic tracking external power supply frequency.
● Big color LCD screen. Large memory, with USB port.
● With anti-false operation function. Automatic adjusting gain during testing and rectifying.
● Anti-interference design.
Specifications
● Capacitance range: 6pF-250μF
● Sensitivity: <0.02pc (capacitance at 50pF)
● Amplifier: 3db low frequency fl 10kHz, 20kHz, 30kHz, 50kHz, 80kHz. / 3db high frequency fh 100kHz, 200kHz, 300kHz, 400kHz, 500kHz.
● Gain adjustment range>120db, gain difference 20±1db, asymmetry of positive/negative pulse response<1db
● Time window: width 1°-360°, can be rotated at any time.
● Test voltage: 0-200kV, error <3% F.S.
● Acquisition channel: 4 or 6channels/card.
● Input impedance: 1MΩ.
● Max. Sampling rate: 20Mhz.
● AD resolution: 12bit, DC accuracy 0.2%.
● Sampling length of each channel: 8M.
● Triggering mode: Manual, internal triggering, external triggering.
● Bandwidth of acquisition card: 3Mhz(-3db).
● Weight: about 15kg.
Product detail pictures:


Related Product Guide:
To create more value for customers is our business philosophy; customer growing is our working chase for OEM Best testing of instrument transformer Factories – GDJF-2006 Partial Discharge Analyzer – HV Hipot , The product will supply to all over the world, such as: United Kingdom, Malaysia, United Arab Emirates, We set a strict quality control system. We have return and exchange policy, and you can exchange within 7 days after receive the wigs if it is in new station and we service repairing free for our products. Please feel free to contact us for further information if you have any questions. We are glad to work for every client.

Company director has very rich management experience and strict attitude, sales staff are warm and cheerful, technical staff are professional and responsible,so we have no worry about product,a nice manufacturer.
