OEM Best UHF PD DETECTOR Factories – GDPD-3000C Portable Partial Discharge Detector – HV Hipot
OEM Best UHF PD DETECTOR Factories – GDPD-3000C Portable Partial Discharge Detector – HV Hipot Detail:
GDPD-3000C Portable Ultrasonic Partial Discharge Detector uses advanced cloud computing and automatic modeling technology to achieve the partial discharge signal measurement, recording, transmission, storage, analysis and exchange, providing powerful technical support for on-site measurement of partial discharge. The measurement personnel collect the partial discharge information by using GDPD-3000C, and the cloud computing can be used to intelligently diagnose the insulation state of detection equipment in real time.
Specification
Hardware
● Processor: high performance intelligent processor.
● Screen: 4.3inch Touch Screen.
● Operation keys: PVE film keyboard.
● Interface:
● 3.5mm stereo headphone interface
● DC LV current charging interface
● USB 2.0 3G wireless network interface
● TF memory card interface
● External probe sensor interface
● TF memory card: 4G-32G.
● Headphones: Min. 8Ω.
● External probe: Ultrasonic probe extension line 250mm.
● Enclosures material: ABS+PC Plastique.
● Weight: 0.7kg;
● Dimension: 241*126*189mm
Operating Environment
● Operation temperature: 0~55℃.
● Operation humidity: 0~90% RH, non-condensing.
● IP rates: 54.
Ultrasonic Sensor Parameters
● Measuring range: -20dBµV~65dBµV.
● Resolution: 1dB.
● Accuracy: ±1dB.
● Sensitivity: -65dB.
● Frequency: 40kHz.
● Diameter: 16mm.
● Test source: 25dB~35dB.
TEV Parameters
● Sensor: Capacitive.
● Measuring range: 0dBµV~60dBµV.
● Resolution: 1dB.
● Accuracy: ±1dB.
● Max Number of Pulses/Cycle: 655.
● Min number of pulses: 5Hz
Power Supply
● Internal battery: 3.7V, 5.6Ah rechargeable Lithium-ion.
● Typical operating time: approx. 6 hours.
● Battery protection: Auto shutdown time, default 10 mins.
● Rated voltage of charger: 90-264V AC.
● Charging voltage/current: 5V/2.4A.
● Charging Time: approx. 9 hours.
Product detail pictures:



Related Product Guide:
We now have a specialist, efficiency workforce to deliver excellent service for our purchaser. We always follow the tenet of customer-oriented, details-focused for OEM Best UHF PD DETECTOR Factories – GDPD-3000C Portable Partial Discharge Detector – HV Hipot , The product will supply to all over the world, such as: Mexico, Sacramento, Myanmar, We will not only continuously introduce technical guidance of experts from both home and abroad, but also develop the new and advanced products constantly to satisfactorily meet the needs of our clients all over the world.

This company has a lot of ready-made options to choose and also could custom new program according to our demand, which is very nice to meet our needs.
