With a positive and progressive attitude to customer's interest, our company continuously improves our product quality to meet the needs of customers and further focuses on safety, reliability, environmental requirements, and innovation of Partial Discharge Calibrator, Electrical Transformers Testing, Vlf Test For Cable, Our tenet is clear all the time: to deliver high quality product at competitive price to customers around the world. We welcome potential buyers to contact us for OEM and ODM orders.
OEM Best Use Of Coupling Capacitor Factories – Partial Discharge Test System GDYT series – HV Hipot Detail:

GIT Series GIS High Voltage Test Sets integrate the high voltage boosting, high voltage measurement, high voltage transformer, high voltage coupling capacitors and all components in a sealed space.
There are two modes to generate high voltage
1) Using reactor inductance and test object capacitance to realize voltage resonance test, to obtain a high voltage, high current from test object.
2) The other one is to obtain required high voltage directly from high voltage transformer.

It is widely used for high voltage, big capacity GIS power equipment insulated withstand voltage test, partial discharge test and GIS transformer accuracy test, suitable for GIS substation, GIS power equipment manufacturer, basin type electrical insulator manufacturer.

Electrical testing equipment
High voltage measurement
Features

● The High voltage obtained are well sealed and shielded in containers, protect the safety of person, no outside interference.
● Accurate test measurement.
● If adding a high voltage sleeve interface, it can lead to high voltage, that can do various high voltage test to traditional high voltage equipment.
● The safest type of high voltage test.

Partial discharge test
pd test of transformer
Specifications

● Output voltage: 100kV, 200kV, 250kV, 300kV, 500kV, 750kV, 1000kV, based on different test objects.
● Capacity: 50-2000kVA, based on different test objects.
● High voltage generated mode: high voltage transformer voltage boost and series resonance (power frequency, frequency conversion).
● All methods of boost voltage are one level voltage boost, no need to cascade boost voltage.
● Input voltage: 0.35-10kV.
● Partial discharge: Rated voltage 3pc (normal environment).
● Impedance voltage: 5%.
● Temperature rise: no more than 65k (50Hz) when rated current operates 60mins.

Power test equipment
PD transformer


Product detail pictures:

OEM Best Use Of Coupling Capacitor Factories –  Partial Discharge Test System GDYT series – HV Hipot detail pictures

OEM Best Use Of Coupling Capacitor Factories –  Partial Discharge Test System GDYT series – HV Hipot detail pictures


Related Product Guide:

Normally customer-oriented, and it's our ultimate concentrate on for being not only one of the most dependable, trustable and honest supplier, but also the partner for our shoppers for OEM Best Use Of Coupling Capacitor Factories – Partial Discharge Test System GDYT series – HV Hipot , The product will supply to all over the world, such as: Egypt, venezuela, Panama, With the aim of "compete with good quality and develop with creativity" and the service principle of "take customers' demand as orientation", we will earnestly provide qualified products and solutions and good service for domestic and international customers.
  • A good manufacturers, we have cooperated twice, good quality and good service attitude.
    5 Stars By Deirdre from Italy - 2017.05.02 18:28
    The factory has advanced equipment, experienced staffs and good management level, so product quality had assurance, this cooperation is very relaxed and happy!
    5 Stars By Wendy from Mombasa - 2017.08.16 13:39

    Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us