Tel: +86-27-85568138

           

    Whats App:

    008613871014953
    • 0
    • 0
    GD-2136H Cable Fault Locating System hits:

    Product Description


    GD-2136H Cable Fault system is important tool to maintain all kinds of cables. It uses various detection way to test cable faults, which is suitable for different levels voltage power cables and communication cables.


    The system contains below units:

    1. GD-2131H Impulse Generator
    2. GD-2132 Cable Fault Locator
    3. GD-2133 Cable Fault Tester
    4. Other accessories



    GD-2131H Impulse Generator


    It’s used to generate HV impulse when using impulse flashover method to detect high impedance fault.


    Features

    • Strong burning ability, max.burning power is 1000W, breakdown point can be burned in short time and the resistance of breakdown point is decreased.
    • If working together with GD-2133 Cable Fault Tester, there are two locating ways:

    a. Low voltage pulse: If only using GD-2133, open circuit and low impedance grounding faults of cable can be located, and the length of cable can be measured or wave speed of cable can be detected.

    b. High voltage flashover: The discharging pulse voltage waveform of fault point is sampled by discharging sphere gap, which can locate fault distance.

    • Generate impulse of fixed frequency. If working together with GD-2132 Cable Fault Locator, there are following functions:

    a. Audio frequency: locate high impedance, flashover faults.

    b. To pinpoint cables route, identify special cable.

    c. To metallic breakdown(dead grounding), using magnetic-field measurement to locate accurately.

    • It also can be used in DC HV withstand test. 



    Specifications

    • Input power supply: AC 220V,50Hz
    • Output voltage: DC 0-32kV (adjustable)
    • Rated power: 2kVA
    • Max.energy: 2048J, 4uF
    • DC flashover voltage: 32kV
    • DC flashover current: 63mA
    • Max.impulse current: 500mA
    • Discharging method: DC HV, one time, cycle
    • Cycle discharging time: 3-6 seconds
    • Environmental temperature:0-40
    • Humidity:<75% RH
    • Altitude:<1000m
    • Insulation level: A
    • Dimension: 430*540*410mm
    • Weight:about 31kg.





    GD-2132 Cable Fault Locator


    Including transmitter, receiver, Inductive probe, potential type detection frame.It is suitable to test all kinds of power cable with metallic conductor. Its main function is locating poor insulation point, detecting circuit   and depth of power cable.



    Features

    • High sensitivity
    • Low static drift
    • High accuracy of locating
    • Anti-interference
    • LCD screen to show signal and status
    • Built-in rechargeable Li-battery.


    Specifications

    Tracing and locating distance: local cable 3km, other cable up to 20km

    • Fault impedance resistance:0-5MΩ
    • Locating accuracy: ≤±10cm.
    • Detection cable depth: <3m.





    GD-2133 Cable Fault Detector


    It can test faults of short circuit, grounding, high impedance leakage, high impedance flashover fault and cable’s poor connectiondisconnection for all kinds of power cables (voltage degree 1kV-32kV) local cable, communication cable,coaxial-cable and metal overhead line.

    It also can measure cable’s length and propagation speed of electric wave speed on the cable. 


    Features

    • Safe, prompt and accurate testing. It uses LV impulse method and HV flashover detection,which test all kinds of cable faults.
    • Using high speed data sampling technology. A/D sampling speed is 100Mhz.
    • Wave form and data automatically display on big LCD screen.
    • Wave form and parameter storage function.
    • Function of comparing testing waveform of cable fault with normal waveform.
    • Wave form extending function.
    • Directly show fault point and testing point direct distance or relative distance.
    • Modify speed of propagation any time according to different testing cables.
    • Built-in rechargeable battery. Small size, portable to carry.

    Specifications

    • Max.testing distance: 15km(Open wire up to 100km) according to customers requirements.
    • Blind detection: 1m
    • Resolution: 1m
    • Power consumption: 5VA
    • Environmental temperature: 0-40℃(limit temperature:-10℃-50℃)
    • Relative humidity: 40(20~90)%RH
    • Atmospheric pressure: 86-106Kpa
    • Size: 275*220*160mm
    • Weight: 1.8kg


    Other accessories

    Other accessories include AF Stethoscope, Headphones, Grounding Pin, PD Locating Rack, RF Tracking Rod.

               
    CONTACT US
    Address: F/10, Block B7, JinYinTan Modern Enterprise City, Dongxihu District, Wuhan, China
    Email: info@hvhipot.com
    Skype: hvhipot@hotmail.com
    Tel: +86-27-85568138
    Fax: +86-27-65606183
    NAVIGATION
  • Company

    Company

  • Product

  • News

  • Services

  • Contact us

  • русский

  • All Rights Reserved Copyright@HV Hipot Electric Co.,Ltd.