    GD6800 Capacitance and Dissipation Factor Tester hits:







    Features

    • Touch LCD screen display.
    • Calendar chip and large storage inside. Save testing result according to time order, check history record and print the result.
    • The instrument data can be exported through U disk, and can be used to view and manage the data through the software on PC.
    • Multiple testing mode, with modes of inside high voltage, outside high voltage, inner standard, external standard, GST/UST, self-excitation. High voltage(more than 10kV) dielectric loss test can be made in the situation of external standard outside high voltage.
    • Test full sealed CVT (Capacitive Voltage Transformer) C1 and C2 dielectric loss and capacitance at the same time. Also test CVT transformation ratio and voltage angle difference.
    • The dielectric loss and capacitance value of C0 in the upper end of CVT can be measured by using the reverse shielding method.
    • High speed sampling signal. Inverter and sampling circuit inside are digitized controlled. Output voltage is adjusted continuously.
    • LCR automatic measurement. Inductance, capacitance, resistance can be measured and displayed.
    • Multiple protection of input voltage fluctuation, output short circuit, over-voltage, over-current, temperature, secure and reliable. Meanwhile, it has the function of grounding testing, that voltage boost is not permitted for non-grounding equipment.
    • No need to dismantle HV lead to measure dielectric loss and capacitance of CVT.
    • Frequency can be changed into 50Hz, 47.5Hz/52.5Hz, 45Hz/55Hz, 60Hz, 57.5Hz/62.5Hz, 55Hz/65Hz.




    Specifications


    Working condition

    -15~60

    RH<80%

    Anti-interference principle

    Frequency conversion

    Power supply

    AC 220V±10%

    Generator can be used.

    High voltage output

    0.5KV~10KV

    Every 0.1kV

    Accuracy

    2%

    Max. current    

    200mA

    Capacity

    2000VA

    Self-excitation power

    AC 0V~50V/15A

    45HZ/55HZ  47.5HZ/52.5HZ

    55HZ/65HZ  57.5HZ/62.5HZ

    Automatic dual frequency

    Resolution

    tgδ: 0.001%

    Cx: 0.001pF

    Accuracy

    ∆tgδ: ±(reading*1.0%+0.040%)

    ∆C x: ±(reading*1.0%+1.00PF)

    Measurement range

    tgδ

    Without limit

    C x

    15pF < Cx < 300nF

    10KV

    Cx < 60 nF

     5KV

    Cx < 150 nF

     1KV

    Cx < 300 nF

    CVT test

    Cx < 300 nF

    LCR measurement range

    L>20H(2kV)

    R>10KΩ(2kV)

    LCR measurement accuracy

    0.1%

    Angle resolution

    0.01

    CVT ratio range

    10~10000

    CVT ratio accuracy

    0.1%

    CVT ratio resolution

    0.01

    Dimension

    Main unit: 350(L)×270(W)×270(H)

    Accessory box: 350(L)×270(W)×160(H)

    Memory capacity

    200 groups, USB flash disk storage is supported.

    Weight

    Main unit: 22.75Kg

    Accessory box: 5.25Kg

     




               
    CONTACT US
    Address: F/10, Block B7, JinYinTan Modern Enterprise City, Dongxihu District, Wuhan, China
    Email: info@hvhipot.com
    Skype: hvhipot@hotmail.com
    Tel: +86-27-85568138
    Fax: +86-27-65606183