  • GD6900  Capacitance & Tan Delta Tester

    GD6900 Capacitance & Tan Delta Tester

    GD6900 measures the capacitance and dielectric loss factor (tgδ) of high voltage electric equipment. It is integrated structure, built-in dielectric loss test bridge, variable frequency adjustable power supply, boosting transformer and SF6 standard capacitor.

  • GDZRC-50U DC Winding Resistance Tester

    GDZRC-50U DC Winding Resistance Tester

    GDZRC-50U DC Winding Resistance Tester is designed to measure DC resistance of inductive devices, such as transformers and power inductors.

  • GDBT-10000kVA/36kV Advanced Transformer Test System for Comprehensive Diagnostics

    GDBT-10000kVA/36kV Advanced Transformer Test System for Comprehensive Diagnostics

    GDBT-10000kVA/36kV is mainly to make no-load and load test, power frequency withstand voltage test, induction withstand voltage test, temperature rising test, DC resistance test and ratio test for 36kV, 10000kVA and below distribution transformers.

  • GDBT Series Transformer Test Bench

    GDBT Series Transformer Test Bench

    GDBT Transformer test system can conduct all routine tests for transformers, including No-load and load test, Induced voltage test, Power frequency withstand voltage test, partial discharge test, DC resistance test, turns ratio test, temperature rising test etc.

     

  • GDZRS-40S  DC Winding Resistance Tester

    GDZRS-40S DC Winding Resistance Tester

    GDZRS series DC winding resistance is a mandatory test item during transformer manufacturing for semi-finished/finished products, factory acceptance tests, installation, commissioning tests, and utility preventive maintenance tests.

  • GDZRC-100U Transformer DC Winding Resistance Tester

    GDZRC-100U Transformer DC Winding Resistance Tester

    Transformer DC winding resistance is a required test item for the factory test, installation, overhaul, change of tap switch, handover test and preventive test of power department.

  • GDB-D Transformer Turn Ratio Tester

    GDB-D Transformer Turn Ratio Tester

    GDB-D Transformer turn ratio tester is designed for three phases transformer in power system and especially for Z type winding transformer and other transformers with relatively large no-load current. 

  • GDOT-80A IEC Standard Insulation Oil Breakdown Tester 80kV

    GDOT-80A IEC Standard Insulation Oil Breakdown Tester 80kV

    There is a large number of electrical equipment in the power system, railway system and large petrochemical plant mines and enterprises, their internal insulation is mostly oil-filled insulation. The dielectric strength of insulating oil is a mandatory routine test. In order to meet the needs of the market, our company developed and produced a series of dielectric oil dielectric strength testers according to the national standard GB/T507-2002(IEC156), the standard DL429.9-91 and the latest power industry standard DL/T846.7-2004. This instrument takes the single-chip microcomputer as the core, realizes all the automation of the test, has high measurement precision, greatly improves the work efficiency, and greatly reduces the labor intensity of the staff. At the same time, the instrument has a compact appearance and is convenient to carry.

  • GDBR-P Transformer Load No-load and Capacity Tester

    GDBR-P Transformer Load No-load and Capacity Tester

    Measure transformer No-load current, No-load loss, short circuit voltage, short circuit loss and capacity.
    Three meters testing methods.

  • GDB-H Handheld Automatic Transformer Turns Ratio Tester

    GDB-H Handheld Automatic Transformer Turns Ratio Tester

    It can accurately measure turns ratio, group and phase angle, which is suitable for all kinds of transformers such as Z type transformers, rectifier transformers, electric furnace transformers, phase-shifting transformers, traction transformers, scott and invert-scott transformers.

  • GDZRC-10U  DC Winding Resistance Tester

    GDZRC-10U DC Winding Resistance Tester

    The measurement of DC transformer resistance is a mandatory test item in transformer manufacturing of semi-finished products, finished products factory test, installation, handover test and preventive test of power department, which can effectively find the manufacturing defects of transformer coil material selection, welding, loose connection parts, missing strands, broken wires and other hidden dangers after operation.

    GDZRC-10U DC Winding resistance tester is a rapid test equipment for measuring the DC resistance of transformers, transformers, generators and motors, and it is a replacement product of single and double arm Bridges. 

  • GD6800 Capacitance and Dissipation Factor Tester

    GD6800 Capacitance and Dissipation Factor Tester

    GD6800 is a fully automatic 10kV insulation power factor/dissipation factor (tan∂) tester designed for condition assessment of electrical insulation in high voltage apparatus such as transformers, bushings, circuit breakers, cables, lightning arresters and rotating machinery.

     

     

     

     