How to judge whether the port of the High Voltage Circuit Breaker Tester is normal
Select [Test]-[Close], there is a real-time status display of 12 fractures below the LCD screen of the high-voltage switch dynamic characteristic tester. The screen shows that under this interface, you can check whether the fracture channel of the instrument is in good condition. If the fracture ...Read more -
Why are transformers divided into oil-type, gas-type and dry-type
what is the difference between oil-type, gas-type and dry-type? In this article, HV Hipot will introduce these three different test transformers for you in detail. Because of the difference in the internal structure of the test transformer, there are three types of test transformers, all of which...Read more -
Precautions for DC Resistance Tester
Transformer DC resistance measurement is a must-test item for semi-finished products, finished products factory test, installation, handover test and preventive test of power sector in transformer manufacturing. Defects and hidden dangers after operation. Transformer DC resistance tester is a rap...Read more -
Operation Introduction for Capacitance & Tan Delta Tester
Description of Capacitance & Tan Delta Tester capacitance &tan delta tester is a very basic method in insulation test, which can effectively check the overall moisture deterioration of electrical equipment insulation, as well as local defects. Different frequency automatic capacitance &am...Read more -
Introduction for SF6 Gas Leak Detector
When choosing and understanding the sf6 gas leak detector, you should be able to pay attention to the information of these tests, and be able to understand these specific problems, and be able to pay great attention to and attach great importance to some of its advantages. Using conditions and en...Read more -
What are the precautions for the use of zinc oxide arrester tester?
Zinc oxide Surge Arrester Tester is an instrument for testing the performance of zinc oxide arrester equipment. It can detect power failure or live state, and can timely find out whether the zinc oxide arrester is aging or damp. It has high measurement accuracy. The use and operation are simple a...Read more -
Brief Analysis of GIS Partial Discharge Detection Method
The current research results of partial discharge in GIS equipment show that due to the relatively high dielectric strength of SF6 gas, the duration of the partial discharge pulse in the high-pressure SF6 gas in GIS equipment is very short, about a few nanoseconds, and the wave head has a very sh...Read more -
DC high voltage generator
The DC high voltage generator meets the on-site DC withstand voltage test and leakage current test of the power sector, so how to select the DC high voltage generator, how to set the standard, what are the conventional and unconventional? ...Read more -
The purpose of transformer AC withstand voltage test
During the operation of power equipment, the insulation will gradually deteriorate under the action of electric field, temperature and mechanical vibration for a long time, including overall deterioration and partial deterioration, resulting in defects. defect. Various preventive test methods, ea...Read more -
Why do AC withstand voltage tests need to be performed on power equipment?
Why do you need to perform AC withstand voltage test on power equipment? The AC withstand voltage test is an effective and direct method to identify the dielectric strength of power equipment. HV Hipot ...Read more -
There are several steps in the operation test of the insulation resistance tester
The insulation resistance tester is mainly used to measure the insulation resistance of large transformers, transformers, generators, high-voltage motors, power capacitors, power cables, arresters and other equipment. GD3127/3128 Insulation Resistance Tester Operation and test st...Read more -
Purpose and test method of AC withstand voltage test for transformer
The transformer AC withstand voltage test is a test in which a sinusoidal power frequency AC test voltage exceeding a certain multiple of the rated voltage is applied to the windings of the tested transformer together with the bushing, and the duration is 1 min. Its purpose is to use a test volta...Read more