Technical

Technical

  • Precautions for Power frequency High voltage test

    Precautions for Power frequency High voltage test

    Some of the main factors that affect the power frequency withstand voltage test are as follows: 1. First of all, we need to choose the appropriate capacity of the test equipment. If the capacity of the test equipment is insufficient or too large, the field test will be affected. 2. The impact of ...
    Read more
  • Why do power cables overheat during operation

    Why do power cables overheat during operation

    With the development of electricity, more and more people rely on electricity in life, and the importance of wire and cable has also been highlighted. We know that wires and cables are used for power transmission. If the wire and cable continue to heat during operation, the temperature of the wir...
    Read more
  • How to reduce transformer partial discharge ?

    How to reduce transformer partial discharge ?

    Measures to reduce partial discharge of transformers 1. Dust control Among the factors that cause partial discharge, foreign matter and dust are very important factors. The test results show that the metal particle with the diameter of Phi 1.5μm can generate much more than 500pC discharge under t...
    Read more
  • Fault analysis and treatment of relay protection

    Fault analysis and treatment of relay protection

    First, relay protection fault analysis 1, current mutual inductance saturation fault The saturation of current transformer to the relay protection of power system is very large. With the increase of the terminal capacity of the distribution system equipment, the short circuit current will be larg...
    Read more
  • How to improve the sensitivity of oil chromatography analyzer?

    How to improve the sensitivity of oil chromatography analyzer?

    Oil chromatography analyzers mainly use differences in boiling points, polarities and adsorption properties of substances to separate mixtures. After the sample to be analyzed is vaporized in the vaporization chamber, an inert gas (i.e., carrier gas, also called mobile phase) is brought into the ...
    Read more
  • Common causes and solutions of short circuit damage to dry-type transformers

    Common causes and solutions of short circuit damage to dry-type transformers

    1. In recent years, dry-type transformer accidents have occurred frequently. From the analysis of dry-type transformer accidents, short-circuit damage has become the main cause of power dry-type transformer accidents, causing great harm to the power grid and seriously affecting the safe operation...
    Read more
  • Knowledge points related to partial discharge tester

    Knowledge points related to partial discharge tester

    Partial discharge refers to electrical breakdown under sharp voltage gradients in insulation systems, usually manifesting as non-sustained, pulse-like discharges.                                                         GDPD-316M handheld partial discharge inspectior 1. Working principle: The par...
    Read more
  • Principles of using Primary Current Generator

    Principles of using Primary Current Generator

    primary current generators can be used as high current test devices or primary current injection testing is a preventive maintenance technique that injects current to evaluate the performance of circuit breakers installed in electrical or automation systems. Because circuit breakers are so critic...
    Read more
  • Common parts of dry transformer short-circuit damage

    Common parts of dry transformer short-circuit damage

    Common parts of dry transformer short circuit damage: 1. The reason for the deformation of the corresponding part under the yoke is: (1) The magnetic field generated by the short-circuit current is enclosed by the oil and oil tank wall or iron core. Because the magnetic resistance of the yoke is ...
    Read more
  • What are the applications of RLC series resonant circuits

    What are the applications of RLC series resonant circuits

    In theory, R has no role in resonance. The resonant frequency depends on the values of inductance and capacitance. In practice, however, smaller ESRs and DCRS need to be considered for proper resonance. What exactly is resonance? It is the stage where the reactance of the inductor is equal to the...
    Read more
  • Standard and test procedure for Tan Delta values

    Standard and test procedure for Tan Delta values

    The dielectric loss value, also known as tan delta, is the residual Angle of the Angle between the current phasor and the voltage phasor flowing through the insulating material under the action of an electric field, which is commonly used to measure the internal energy loss of the insulating mate...
    Read more
  • Importance of oil flash point determination

    Importance of oil flash point determination

    Flash point refers to the temperature at which a flash fire can occur on the oil surface when a flame is passed over the steam and air mixture escaped from the heated oil at certain intervals under specified heating conditions, expressed in °C. The flash point of the oil indicates the flammabilit...
    Read more

Send your message to us: